The percentage values in this chart correspond to the percentages listed in the Main, Length, and Abnormal
ID Sensor Tables. For example, if the value is 10%, the toner supply clutch is on for 10% of the time; it
switches on for 0.3 s at 3.0 s intervals
Toner End/Near-End Detection
The machine compares Vsp/Vsg with two SP settings to find when the toner cartridge is almost empty (Toner
Near End) or fully empty (Toner End).
• SP2927-1: Near End Level
Development