25/32
FV-L030B1
User’s Guide Rev. 1.01
4.4.2
Descriptions of the Camera Control Commands
(The underline settings are the factory default settings)
Command No.
Command Descriptions
10H:
MOD1[7O0]
[Camera function mode setting 1] Initial data: 09H
Sets the following camera function mode.
D[7O0]
D7
D6
D5
D4
D3
D2
D1
D0
D7:
Continuous / Trigger Mode
0: Auto
1: Manual
D6:
Trigger Polarity
0: Positive
1: Negative
D5:
Trigger Mode
0: Edge Preset
1: Pulse Width
D4:
Binning Mode
0: OFF (Normal)
1: ON (Binning)
D3:
Scanning Mode
0: Full scanning
1: Partial scanning
D2 to D0:
Reset Mode
000: Non-Reset
001: V-Reset
010~111: No function
(Prohibited setting. Please do not use these)
When D7 is set to “0: Auto”, a camera will detect its operational mode based on the input trigger signal.
If the input trigger signal is kept at high, the camera operates in the continuous mode, assuming the trigger polarity
is set to positive.
11H:
MOD2[7O0]
[Camera function mode setting 2] Initial data: 32 (20H)
Sets the following camera function modes.
D[7O0]
D7
D6
D5
D4
D3
D2
D1
D0
D7
HD / VD direction
00H: SP2 and SP3 as inputs
01H: SP2 and SP3 as outputs
10 to 11H: (Prohibited setting. Do not set these values)
D6 to D5
Frame rate
00H: 60fps
01H: 90fps
10H: 30fps
11H: No function
D4
Smear Half Reduction
0: OFF
1: ON
D3
Function Mode
0: Trigger Mode
1: Continuous Mode
D2 to D0:
Partial Scanning
000: Full scanning
001: 1/2 partial scanning
010: 1/4 partial scanning
111: Variable partial scanning
011~110: No function (Prohibited setting. Do not set these values)
Function mode is enabled when the “Continuous/Trigger” mode selection (MOD[7] is manual (set as 1).
No video output without the trigger signal input while the camera works with the trigger mode.