background image

 
 
 
 

 

1/14 

FV-G200B1 
Product Specifications Rev. 1.03 

 
 

GigE Vision   

UXGA Monochrome CCD Camera 

 

FV-G200B1 

 

 

Product Specifications 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

RICOH COMPANY, LTD. 

Summary of Contents for FV-G200B1

Page 1: ...1 14 FV G200B1 Product Specifications Rev 1 03 GigE Vision UXGA Monochrome CCD Camera FV G200B1 Product Specifications RICOH COMPANY LTD ...

Page 2: ...correct and up to date Sentech assumes no liability legal or otherwise for any errors in listings specifications part numbers process software or model applications Sentech reserves the right to change specifications product descriptions product quality pricing and application at any time without prior written or oral notice Any party using such information assumes all risk for any and all damaged...

Page 3: ...ns 4 2 Electronic Mechanical Environmental Specifications 6 2 1 Spectral Sensitivity Characteristics 8 3 Connector Specifications 9 3 1 RJ45 Connector 9 3 2 DC Iris Lens Connector 10 3 3 Power I O connector 10 3 3 1 Equivalent Circuit for the Input Pin of the I O Connector 12 4 Dimensions 13 ...

Page 4: ...tus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications For Canada WARNING TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE 1 Safety Product Precautions Safety Precautions Product Precautions Handle the camera with care Do not abuse the camera A...

Page 5: ... a general purpose electronic device using the camera for the equipment that may threaten human life or cause dangers to human bodies directly in case of failure or malfunction of the camera is not guaranteed Use the camera for special purposes at your own risk ...

Page 6: ...seconds Pulse width mode 1 useconds to Unlimited ALC Auto iris lens electronic iris and AGC ON OFF Gain 0 to 20 4 dB Gamma Gamma 1 0 Factory default or uploadable gamma table AOI Function Programmable AOI setting via the communication Smear Reduction Selectable ON OFF via the communication Operational Mode Free run Edge preset trigger Pulse width trigger unlimited long exposure Communication UART ...

Page 7: ...eleration 38G half amplitude 6ms 3 directions 3 times each Standard Compliancy EMS EN61000 6 2 EMI EN55011 FCC PART15 subpart B classA Environmental Specifications RoHS RoHS Compliant Note Please use this camera in surrounding temperature conditions that are less than 35 C or in conditions where the camera s top case plate is less than 65 C When the camera is used in surrounding temperatures that ...

Page 8: ...8 14 FV G200B1 Product Specifications Rev 1 03 2 1 Spectral Sensitivity Characteristics 1 0 8 0 4 0 6 0 2 0 400 500 600 700 800 900 1000 Relative Response Wave length nm ...

Page 9: ... being used is 1Gb transferring Damaging or mishandling the CAT5e cable may cause the transferring speed to change from 1Gb to 100Mb If this happens please replace the CAT5e cable Green LED Yellow LED Status Green Light ON Orange Light ON Power ON Green Light ON Orange Light Blinking 1Gb Transferring Light OFF Orange Light Blinking 100 Mb Transferring Power I O Connector DC Iris Lens Connector RJ4...

Page 10: ...No 2 I O 1 and Pin No 3 I O 2 Pin No Signal Name IN OUT Voltage 1 GND IN 0V 2 I O 1 OUT 3 3V LVTTL 3 I O 2 OUT 3 3V LVTTL 4 TRG_In IN 5 TRG_In IN Low Smaller than 1 0V Opt Isolated High 3 0 to 26 4V Opt Isolated potential difference between TRG_In and TRG_In 6 POWER IN IN 10 8 to 26 4 Vdc Command No HR10A 7R 6PB Hirose F0H 3 0 F1 3 F0H 7 4 F1 4 For I O 1 Pin No 2 For I O 2 Pin No 3 I O 1 Pin No 2 ...

Page 11: ... No 13H to accept the trigger signal while the image outputs The noise appears on the image when the exposure begins while the image is output The noise appears on the image when the start exposure while the image is output In this case please change the H reset for the exposure start mode Device code 00H Command No 12H to change the exposure start point to the next HD timing 2 UserOutput The stat...

Page 12: ... 3V 3 3V 3 3V TOSHIBA RN1105MFV TOSHIBA RN1105MFV 2 1 3 TOSHIBA TLP181 TOSHIBA TLP181 3 4 6 1 2 2K 2 2K 1 2 3 4 5 6 TOSHIBA RN1105MFV TOSHIBA RN1105MFV 2 1 3 1K 1K 1K 1K 10 8 to 26 4V Trigger_In Trigger_In IO_Out IO_Out GND Customer GND 3 to 26 4V 3 to 5mA Trigger Signal HR10A 7R 6PB HIROSE or equivalent connector ...

Page 13: ...13 14 FV G200B1 Product Specifications Rev 1 03 4 Dimensions Unit mm ...

Page 14: ...beOut is corrected to StrobeSignal 1 02 2012 07 03 Updated Document title Electronic Specifications Shutter Speed Exposure Time The maximum value for the Exposure Time is corrected to 16 777 215 Equivalent Circuit for the Input Pin of the I O Connector 1 03 2012 08 25 Updated Pin Assignment of Power I O Connector RICOH COMPANY LTD URL http www ricoh com fa_security ...

Reviews: