PREPARED BY: Y. Okunishi
CHECKED BY: M. Iwasa
FROM: 2nd T.S. Section
CLASSIFICATION:
Action Required
Revision of service manual
Troubleshooting
Information only
Retrofit Information
Other
MODEL: Fax3500L(USA),
NRG9665(USA), Savin Fax3670
Fax5600L(USA),
Lanier Fax7550, Omnifax L540
Problem: The Paper Feed Unit may not work correctly.
Cause:
Wires of the harness (H511 5528) from the FCU to the relay connectors for the paper
feed unit (PFU) are not allocated properly.
Affected machines:
Fax 3500L
S/N R8750600001 ~ R8750700600
NRG9665
S/N 6355060620 ~ 6355060671
Savin Fax 3670
S/N 0950600001 ~ 0950700120
Fax 5600L
S/N M2050600001 ~ M2050700500
Lanier Fax 7550
S/N L7555060677 ~ L7555060780
Omnifax L540
S/N L5405060271 ~ L5405060330
Action Required:
The harness should be checked before the start of the PFU installation because the
FCU or the PFU PCB may become damaged.
Follow the attached procedure before PFU installation and change the harness
to a new one if it is bad.
Technical Bulletin
No. Multi-003
SUBJECT: Harness for PFU
DATE:
July 31, 1995
Page 1/2