Installation 4-12
II
L
00
11) Connect the connector of cables to the Printer and Transit Pass Unit Type DDP.
(1) Pass the three cables through the Hole of Printer and Transit Pass Unit Type DDP from
Transit Pass Unit Type DDP to Printer.
- AC cable (white 2pin connector)
- Signal cable (black 20pin / black 20pin / black 14pin connector)
- GND cable
(2) Pass the one cable through the Hole of Printer and Transit Pass Unit Type DDP from
Printer to Transit Pass Unit Type DDP.
- FNS IF cable (white 4pin / black 20pin connector)
(3) Disconnect the FNS I/F cable from J745 connector on the CP board.
(Disconnection 1)
(4) Connect the Signal Cable to the connector on the CP board as follows.
(Connection 1)
- black 20pin connector (big size)
-> J745
- black 20pin connector (small size)
-> J747
- black 14pin connector
-> J791
(5) Connect the AC cable to the J236 on the Low Voltage Power Supply of Printer. At this
time, connect the CE AC cable that is disconnected from J236 to the white 2pin
connector of the AC cable.
(Connection 2)
(6) Mount the FG cable on Printer frame by using M4 screw.
(Connection 3)
(7) Connect the FNS IF cable to the white 4pin connector in the Transit Pass Unit Type
DDP.
(Connection 4)
(8) Connect the AC cable to the white 2pin connector in the Transit Pass Unit Type DDP.
(Connection 5)
(9) Switch on No.8 of SW1 on the CP board of the Printer.
(10) Switch on No.6 of SW2 on the CP board of the Printer.
Note 1) Green flat cable of FNS IF cable is
not
used.
Note 2) Signal Cable (CS) in the Transit Pass Unit Type DDP is
not
used.