2.Replacement and Adjustment
24
[1]: Paper feed sensor (S1)
[2]: Upper limit sensor (S4)
[3]: Paper end sensor (S3)
[4]: Transport sensor (S2)
Each sensor except for the tray upper limit sensor is common part.
Metal cover [A] for antistatic control has been added to the following sensors:
•
Paper Feed Sensor (S1)
•
Transport Sensor (S2)
•
Paper End Sensor (S3)
When replacing the those sensors, this cover will also be used after replacement, so remove it
from the old sensors. When you do so, be careful not to deform or damage anything.
4.
Remove the paper feed sensor [A].