background image

4.3.1 Live

.......................................................................................................................................

- 27 -

4.3.2 Add user

..............................................................................................................................

- 28 -

4.3.3 User management

............................................................................................................

- 28 -

4.3.4 Records query

...................................................................................................................

- 29 -

4.4 Settings

.......................................................................................................................................

- 29 -

4.4.1 Net config

............................................................................................................................

- 29 -

4.4.2 System Config

...................................................................................................................

- 30 -

5. Maintenance

....................................................................................................................................

- 31 -

6. Specification

.....................................................................................................................................

- 31 -

7. Warranty

............................................................................................................................................

- 33 -

Summary of Contents for V2 Pro

Page 1: ......

Page 2: ...the scanning process Do not place unit outside in rain or weather The system detects skin surface temperature which is typically 1 F lower than internal body temperature If you have trouble setting u...

Page 3: ...61000 3 3 2013 A1 2019 EN 55035 2017 FCC inspection test certificate number BKC200508AC in line with the following standards FCC PART 15 Subpart B RoHS test certificate number BKC200509AC in line wit...

Page 4: ...3 1 Login interface 6 3 2 Settings 9 3 2 1 Account 9 3 2 2 System 9 3 2 3 Maintenance 10 3 2 4 Screen 11 3 2 5 Network 12 3 2 6 Advanced 13 3 2 7 Storage 15 3 2 8 AI settings 15 3 2 9 Face library 17...

Page 5: ...4 3 1 Live 27 4 3 2 Add user 28 4 3 3 User management 28 4 3 4 Records query 29 4 4 Settings 29 4 4 1 Net config 29 4 4 2 System Config 30 5 Maintenance 31 6 Specification 31 7 Warranty 33...

Page 6: ...Pro is the ultimate all in one solution for contactless temperature screening 1 1 Features ADA Compliant full customization of data storage and display RTSP live feed for security camera integrations...

Page 7: ...Please follow the network setup tutorial on our website https www richtech ai com tutorial videos Once the system is setup on your network simply open IE 10 and navigate to the static IP address you a...

Page 8: ...e Note we recommend using Window 10 when managing the AATSS V2 pro 2 1 V2 pro connect to the network If you need to manage the V2 pro through a network please connect the base to your router through a...

Page 9: ...below The default mode of V2 pro to connect to Internet is DHCP Dynamic Host Configuration Protocol Device will be obtained the IP address automatically How to check the IP address there will be appea...

Page 10: ...follow the guide to download plug in and log into the web terminal Default username Admin Password 123456 In Network LAN please close the enabling of DHCP Then click the Save button to save the settin...

Page 11: ...gin interface When you open the management terminal web first time please input the device IP address e g http 192 168 0 8 There is note to recommend you to install the extension please click install...

Page 12: ...7...

Page 13: ...8 Default username admin Password 123456 Camera life feed real time monitoring screen...

Page 14: ...ttings 3 2 1 Account You may change the username and password and add a user that only have access to browse date no permission to change settings 3 2 2 System a System Info You can change the device...

Page 15: ...Upgrade Step 1 Click Browse and select the firmware update file s then client upgrade button to upgrade Step 2 Click client upgrade to update the system Step 3 Then perform a Factory Reset to restarte...

Page 16: ...11 b System log 3 2 4 Screen Screen Parameter Options Auto mode Always bright Time...

Page 17: ...12 3 2 5 Network...

Page 18: ...SMS email address Not all carriers are listed Carrier Email Format AT T number txt att net T Mobile number tmomail net Verizon number vtext com Sprint number messaging sprintpcs com Xfinity Mobile num...

Page 19: ...14 b FTP Can be used to transfer files from the device to your pc c RTSP Full camera feed streaming provides easy integration into existing security camera systems...

Page 20: ...15 3 2 7 Storage You can see the device s available storage here 3 2 8 AI settings...

Page 21: ...setting the faster the system can recognize faces However it may recognize other objects as faces if the setting is too low Snapshot pixels Customize Automatic Minimum Snapshot Pixels 220 30 300 Maxim...

Page 22: ...nge 98 6 99 5 F 37 0 37 5 c Other Config FTP Upload Enable Face Tracking Enable Enable Green square will be shown on the screen to display face tracking Disable 3 2 9 Face library You can import pictu...

Page 23: ...18 You can preview the image here...

Page 24: ...the similarity range from 0 easier to recognize to 100 difficult to detect The default setting at 85 provides strong security while allowing reliable and consistent recognition You can check all the...

Page 25: ...lay Disable Option to display user s info Temperature display Show Option to display the temperature Save Snapshot Enable Option to save snapshot Save Temperature Record Enable Option to save temperat...

Page 26: ...21 3 2 11 Error Message You can set error message as you will 3 2 12 Volume Here you can adjust the volume settings enable audio or disable it...

Page 27: ...ee below steps 1 Use ethernet cable to connect v2 pro and pc 2 Open the Desktop management terminal obtain the v2 pro IP address and gateway address e g 192 168 1 8 3 PC IP address should be static ad...

Page 28: ...23 4 Desktop Management Terminal 4 1 Setup please install the ConfigTool for AATSS V2 pro on your pc Installation steps Download the ConfigTool then install it as below...

Page 29: ...24...

Page 30: ...you can see a list of all your AATSS V2 Pro devices IP addresses firmware versions and other details You can apply updates to multiple devices through this terminal as well as view data and adjust set...

Page 31: ...rt Click support it appears software information 4 2 2Setting Click settings if there is more than one NIC and devices couldn t be showed on list you need to change the IP address by Select Network Ad...

Page 32: ...1 Live This screen provides a live feed of all temperature screenings currently being conducted If an abnormal temperature is detected the system will provide an audible alarm to notify the person vi...

Page 33: ...28 4 3 2 Add user Here you may add users to the whitelist blacklist and uncategorized databases 4 3 3 User management Here you can edit user information...

Page 34: ...29 4 3 4 Records query You can find all records here 4 4 Settings 4 4 1 Net config You can set the IP address here please use a static IP address...

Page 35: ...30 4 4 2 System Config You may adjust system settings and reboot the device here You may change the photo right below the screen format 24 bit BMP resolution 285x179 see below...

Page 36: ...ro please avoid heat sources such as vents and hot electronic equipment Standard cleaning products can be used to clean the system We recommend restarting the device once a day to ensure normal functi...

Page 37: ...one Wiegand 26 34 input Dry contact LAN 1 RJ45 Ethernet socket INFRARED THERMAL MODULE Temperature Detection Distance 1 6 2 6 ft Measurement Resolution 0 018 F Temperature Measurement Accuracy 0 5 F M...

Page 38: ...r manufacturer warranty Extendable up to 3 years More information Return within 14 days of receiving shipment for a full refund minus return shipping If return is due to manufacturing defect all shipp...

Page 39: ...1 www richtech ai com service richtech ai com 1 866 204 2158...