©2021 RICHTECH INDUSTRIES
1.800.677.7791 RICHTECHINDUSTRIES.COM
3
This system is designed to operate reliably with an
SLA Deep Cycle Marine Battery (not included).
The use of an AGM battery is strongly recommended.
The use of wet-cell batteries is strongly discouraged.
Automotive batteries are not suitable for this
application and will result in system failure.
WARNING: TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK OR INJURY:
• WEAR SAFETY GLASSES WHEN CONNECTING OR
DISCONNECTING THE BATTERY.
• KEEP SPARKS AND FLAMES AWAY FROM THE
BATTERY.
• KEEP METAL TOOLS FROM CONTACTING THE
BATTERY POSTS AND CREATING A SHORT
ACROSS THE TERMINALS. A SHORT CIRCUIT MAY
CAUSE AN EXPLOSION.
• FOLLOW ALL INSTRUCTIONS PUBLISHED BY THE
BATTERY MANUFACTURER. FAILURE TO DO SO
MAY RESULT IN PROPERTY DAMAGE, SERIOUS
INJURY OR DEATH.
The Pitboss Battery Backup System displays system information on the
Message Center. There are two types of messages:
Informational
and
Alarms
.
Informational
messages do not require immediate attention and do not
sound an alarm. If more than one message is active, they rotate on the
display.
Alarm
messages require your immediate attention and will sound the
unit’s audible alarm. If more than one alarm is active, they rotate on the
display. Alarm messages take precedence over information messages,
no informational messages are displayed when there is an active alarm.
The Pitboss Battery Backup System is an automatic
system and will automatically operate during a power
outage or when the primary sump pump fails to
operate. The System automatically maintains and
recharges the battery.
The Pitboss Battery Backup System performs a full
system test once per week. The system will cycle
the backup pump and test the battery performance.
If any issues are found during the self test, the
appropriate alarm message will be displayed, and the
audible alarm will be activated.
The Pitboss Battery Backup System features two
push buttons on the controller.
The PUMP TEST button activates the backup pump.
The pump will continue to run as long as the button
is pressed. Do not run the backup pump in a dry
sump pit for extended periods.
The ALARM MUTE button will silence the audible
alarm for 24 hours when pressed. It will also clear
the alarm message from the LCD screen, so take
note of the cause of the alarm. If the same alarm
repeats during the 24 period, the audible alarm will
not sound. If a different alarm is triggered during
this period, the audible alarm will sound. Pressing
the alarm mute button a second time will cancel the
alarm mute.
To activate the weekly system test, press and hold
the ALARM MUTE button. This will activate the full
system test sequence.
INFORMATIONAL MESSAGES
System OK
Displayed when no messages
active or after alarm muted.
System is working properly
Pump
Running
Displays when the pump is on,
showing in seconds the length
of time the pump is on.
System is working properly
AC Power
Failure
Displayed if AC power is lost.
Check that unit is plugged in.
Check GFI/breaker for trip.
Normal during power loss.
ALARM MESSAGES
Reverse
Polarity
Battery Red/Black leads are
connected backwards.
Connect leads to correct terminals.
PWR OK/
Backup On
Backup pump is on while AC
power is present.
Check primary sump pump for
proper operation. Replace sump
pump if necessary.
CHECK
PUMP
Backup pump active but no
current draw is detected.
Check that pump cord is firmly
connected to controller jack. Call
for service.
Batt Low
Voltage
Battery voltage drops below
11.4 volts (50% discharged).
Check that unit is plugged in. Check
GFI/breaker for trip. Normal during
extended power loss.
Batt Crit
Voltge
Battery voltage drops below
10.4 volts (90% discharged).
Check that unit is plugged in.
Check GFI/breaker for trip. Replace
battery if power remains out.
Auto Test
Failed
System fault detected
during system self-test.
Alarm message will be
displayed alternately.
Correct the issue in the displayed
alarm message.
Excessive
Runtime
Backup pump has run more
than 50 seconds.
Check that backup float sensor can
move freely, not caught on wires.
Normal during extremely heavy
rains.
Check
Fuse / Batt
Blown Fuse
Check that pump cord is firmly
connected to controller jack. Call
for service.
Batt Not
Detected
No battery is detected.
Check battery connections. Replace
battery if necessary.
BATTERY INFORMATION
SYSTEM OPERATION
USING THE
CONTROLLER BUTTONS
MESSAGES