Richmar DVTREX-L User Manual Download Page 7

The REX Recovery Exercise X-trainer is intended to temporarily relieve minor muscle aches 
and/or pains, and to temporarily increase circulation to the treated areas.  

4. GENERAL SPECIFICATIONS 

5. INDICATIONS FOR USE 

6. CONTRAINDICATIONS 

The REX Recovery Exercise X-trainer includes the main pump, dual lower extremity garments 
and backpack.

GARMENT

Garment size (customer size is available):

MAIN MACHINE

* Power supply cord and cable can be only replaceable by service personnel. 

DIMENSIONS:

WEIGHT:

Power:

Power Plug:

Power Cable:

Garment Material:

Therapy Time:

Min/Max Pressure:

Number of Chambers per Garment:

Cycle Time:

285mm H x 175mm W x 130mm D
2.6 Kg
110-125Vac 60Hz 50VA
JL-201 AC125V 10A 2-pole without earthling contact.
NISPT-1 2*0.824mm
Thermoplastic Urethane
0-30 mins
20-200mm Hg
4
70s

REF

DVTREX-LE-L
DVTREX-LE-U

Length

(inch/cm)

44/110
44/110

Width

(inch/cm)

14/35
16/40

• 

DO NOT

 use this product if you are experiencing inflammation, an infection, pain of unknown 

origin, or bleeding (internal or external) at or near the site of application or if you have a wound 
at or near the site of application.

• 

DO NOT

 use-this product if you have any of the following conditions:

 

° Acute pulmonary edema

 

° Acute thrombophlebitis

 

° Acute congenerative cardiac failure

 

° Acute infections

 

° Patients with documented deep vein thrombosis

 

° Episodes of Pulmonary embolism

 

° Wounds lesions or tumors at or in the vicinity of application

 

° Where increased venous and lymphatic return is undesirable

 

° Bone fractures or dislocations at or in the vicinity of application 

5

 

Summary of Contents for DVTREX-L

Page 1: ...Combo Pneumatic Compression System USER MANUAL 3507 22 01 A...

Page 2: ...TY PRECAUTIONS 3 4 GENERAL SPECIFICATIONS 5 5 INDICATIONS FOR USE 5 6 CONTRAINDICATIONS 5 7 SYSTEM AND COMPONENTS 6 8 OPERATING INSTRUCTIONS 7 9 MAINTENANCE AND STORAGE 10 10 DEVICE STORAGE 11 11 TROU...

Page 3: ...trainer has a pump and dual lower extremity garments with air cells The patient puts the garments on the pump inflates the air cells to compress muscles promote venous blood return and to help preven...

Page 4: ...e 104 F 40 C On back of device and instruction manual On back of device On back of device On back of device On garments On back of device The Pump is Class II Protection The garments is Type BF Applie...

Page 5: ...d sunburned bruised or broken skin or with skin conditions such as skin cancer dermatitis eczema or psoriasis in or around treat ment sites Should changes in skin appearance occur such as blisters red...

Page 6: ...will void the warranty DO NOT hold the unit or attachments by the tubing DO NOT wrap the tubing around the garments as it could cause damage to the tubes not covered by the warranty DANGER WARNINGS On...

Page 7: ...JL 201 AC125V 10A 2 pole without earthling contact NISPT 1 2 0 824mm Thermoplastic Urethane 0 30 mins 20 200mm Hg 4 70s REF DVTREX LE L DVTREX LE U Length inch cm 44 110 44 110 Width inch cm 14 35 16...

Page 8: ...CONTROLS DISPLAY 7 SYSTEM AND COMPONENTS Pneumatic Compression Pump Garments for Leg Use Position Setting Mode Setting Power On Off Timer Setting Pressure Setting Start Pause 6...

Page 9: ...ents on each leg and pull up the zipper NOTE Lower Extremity Garments inflate deflate simultaneously and tubing is already attached to the garments Must put both garments on to work properly 3 Connect...

Page 10: ...eutic Mode A or B 6 Set the timer by choosing between 10 20 or 30 mins When the timer is done the device will automatically stop and go into standby mode NOTE Recommended treatment time is 30 mins per...

Page 11: ...The max pressure of the pump core is 230 to 260mmHg The max flow of the pump core is 16L 18L min 8 Position Setting Press corresponding number shown below based on how many chambers you want to inflat...

Page 12: ...amp not wet cloth using mild soap and water solution once per month as needed Garment Cleaning Disinfecting Instructions 1 Disconnect garment from device Open garment to expose all sides either by sep...

Page 13: ...e and or loud noises Move to a more stable and even surface 10 DEVICE STORAGE The device should be stored in a clean dry area between 59 to 77 F 15 to 25 C However short term exposure to temperatures...

Page 14: ...discharge ESD IEC 61000 4 2 8kV contact 2kV 4kV 8kV 15kV air 8kV contact 2kV 4kV 8kV 15kV air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative...

Page 15: ...this device is used exceeds the applicable RF compliance level above this device should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary...

Page 16: ...between portable and mobile RF communications equipment transmitters and the device as recommended below according to the maximum output power of the communications equipment For transmitters rated at...

Page 17: ...sumer or during transport to the retailer Accessories which are subject to normal wear and tear Liability for direct or indirect consequential losses caused by the unit is excluded even if the damage...

Reviews: