3.8 SCT-20 EtherNet/IP™
The SCT20-IP works as a device in a EtherNet/IP network.
3.8.1 Instrument Setup
1. Press and hold
and .
displays.
2. Press or until
displays. Press
.
3. Press or to navigate through menu.
•
: select the reading/writing of the byte in LITTLE-ENDIAN or BIG-ENDIAN mode
–
: BIG ENDIAN
–
: LITTLE ENDIAN (default)
•
: set instrument IP address (default: 192.8.0.141)
•
: set instrument Subnet Mask (default: 255.255.255.0)
•
: set Gateway address of Ethernet network (default: 192.8.0.111)
4. Press until
displays to apply changes.
Load the included EDS file (Ethernet_20.eds) in the EtherNet/IP scanner’s development instrument; or, open Class 1 I/O
Connection with the following settings:
Figure 3-1. Module Properties (EtherNet/IP)
• If explicit messages are used and the PLC supports class 3 connections (with appropriate interface), insert the data
shown in
.
• If explicit messages are used and the PLC needs data read/write messages to be constructed manually use the settings
in
. The arrays dimensions of exchanged data are the same as those reported in
Field
Read
Write
Service
0x0E
0x10
Class
0x04
0x04
Instance
0x65
0x64
Attribute
0x03
0x03
Data
NO
Byte array to be written
Table 3-16. Manual Settings for Communication