Operation
15
3.4
Multi-Range Function
The multi-range function allows for subdividing the scale capacity in two, each up to 3000 divisions.
Example: with a 10 kg cell platform it is possible to approve the weighing system with:
Single range: 6 kg capacity and 2 g division (3000 div.)
Dual range: 6/3 kg capacity and 2/1 g division (3000 + 3000 div.)
Multi-range functioning is indicated by illumination of the relative LED identifying the operating range; when
the weight on the scale enters into the second range, the division of the second range is enabled. The first
range division is restored only when the weight on the scale goes below the gross zero of the scale.
The selection of the range number with multi-range functioning is made during the instrument’s calibration.
See
.
3.5
Optional Date/Time Adjustment
The instrument can be equipped with a date/time option. To set the date/time:
1. Turn on the instrument and press
while the firmware version displays.
displays.
2. Press
to enter the menu.
3. Press
or
until
displays. Press
to enter the menu.
4. Enter the date and time in the following order: day, month, year, hour and minutes. Each entry must be
confirmed by pressing
.
5. Slowly press multiple times until
displays.
• Press
to confirm and store to the instrument memory
• Press any other key to cancel and exit without saving
The
parameter is not displayed if the date/time option is not installed.
3.6
Optional Display Saver
If the instrument is equipped with the date/time option, it is possible to enable a display saver. The time displays in
the HH-MM.SS format after there is no activity for the time specified and the scale is unloaded. The instrument
returns to the weigh mode when a weight variation is detected, or a key is pressed.
To set the screen saver function:
1. Turn on the instrument and press
while the firmware version displays.
displays.
2. Press
to enter the menu.
3. Press
or
until
displays. Press
to enter the menu.
4. Press
or
t
o scroll through the options.
•
– disabled,
•
– enabled
5. Press
to confirm. If
is selected a prompt to enter the number of minutes after which the
instrument displays the time.
6. Enter a number between 1 and 255 using
to select the digit to be modified and
or
to decrease or
increase the digit.
7. Press
to
confirm.
8. Slowly press multiple times until
displays.
• Press
to confirm and store to the instrument memory
• Press any other key to cancel and exit without saving
The
parameter is not displayed if there is no date/time option.
Note
C
Note
C
Note