Installation
© Rice Lake Weighing Systems
●
All Rights Reserved
3
2.0
Installation
Use this section to unpack and install the scale.
2.1
Scale Location
IMPORTANT
The scale must never be loaded beyond its capacity, even momentarily.
• Select a site where overweight loads can maneuver easily without crossing the platform.
• Avoid areas where damage could occur from side impacts of wheels or forklift tines.
• Avoid areas where falling objects could cause shock damage.
• Avoid areas where water may damage a scale not meant for a wash-down environment.
• The scale must be level within 1/4''. Choose a site where the floor is level to this standard to avoid excessive shimming.
The floor may require modification if unable to select and area up to standard.
• For systems where the scale is connected to a 120V AC circuit, the instrument must be directly connected to an earth
ground with a ground interface cable of no more than 3
resistance throughout its length.
2.2
Unpack Floor Scale
Remove all packing material and inspect scale for visible damage caused during shipment. Report any damage to the shipping
company and Rice Lake Weighing Systems immediately.
CAUTION
Prior to lifting the scale, ensure the top plate is locked by securing the tool-less top plate lock down.
Figure 2-1. Top Plate Lock Down
Figure 2-2. Proper Lifting Technique
IMPORTANT
Lift the scale only with a properly designed spreader bar as shown in
.
Lifting force must be vertical to avoid bending the eye bolts.
WARNING
Eye bolts must always be inserted into the top of the scale. Lifting should always occur with the top plate facing
up and the eye bolts securely attached through the nuts welded to the bottom side of the top plate. Lifting from
the bottom of the plate could cause nuts to break loose and the scale to fall.
Single Chain Lift
Double Chain Lift
1/2-20NF Eye Bolts
PN 17709