Installation
©
Rice Lake Weighing Systems
●
All Rights Reserved
5
2.3 Floor Installation
For permanent applications, the scale should be secured to the floor to prevent sideways movement. Each scale frame corner
contains an anchor mounting hole under a removable cover. Perform the following to install the scale to the floor:
WARNING: Before proceeding, ensure floor is suitable for anchoring.
1. Remove the four Phillips machine screws securing the load cell cover to frame. Retain screws for reuse.
2. Pull the cover away from the frame to remove.
Figure 2-2. Load Cell Cover Retaining Screws
3. Using the corner 3/4 in (19 mm) anchor hole as template, drill pilot hole into the floor suitable for anchor bolt.
4. Bolt the scale frame corner to the floor using an anchor bolt (not included).
Figure 2-3. Scale Corner Anchor Hole
5. Reinstall load cell cover to frame with four machine screws.
6. Repeat steps for remaining corners.
Machine Screws
Load Cell Cover
3/4 in (19 mm)
Anchor Hole