RoughDeck LP
6
Visit our website
2.4 Connecting Indicator Interface Cable
The junction box terminal block (
) is used to connect four load cells and the main cable to the indicator.
Each scale kit includes 20 ft (6.1 m) of 6-wire cable to connect the junction box to an indicator. The interface cable between the
scale and the indicator must be protected against crushing, cutting or moisture damage (
). Perform the
following to complete junction box connections:
1. Remove four hex screws from the junction box access cover. Retain screws for reuse.
2. Pull the panel away from the frame to remove.
Figure 2-4. Junction Box Access Cover
3. Remove six Philips screws from the junction box cover. Retain screws for reuse.
4. Pull the cover away from the frame to remove.
Figure 2-5. Removing Junction Box Cover
Hex Screws
Junction Box Cover
Phillips Screws
Cover