![Rice Lake RoughDeck FXB Installation Manual Download Page 9](http://html1.mh-extra.com/html/rice-lake/roughdeck-fxb/roughdeck-fxb_installation-manual_1454224009.webp)
Installation
© Rice Lake Weighing Systems
●
All Rights Reserved
5
2.2 Inspecting the RoughDeck FXB
1. Inspect the unit for signs of damage such as a bent frame, broken or bent flexures and broken welds. This visual
inspection is very important and should be performed with great care.
2. Verify that all gripper plate bolts are tight (four bolts holding each flexure plate in place).
.
Figure 2-2. Gripper Plate Bolts
2.3 Site Preparation
Do not locate the scale where overweight loads would have to maneuver to avoid crossing the platform. Use the following
guidelines for site preparation:
• For scales not meant for washdown environments, avoid areas where water may cause damage.
• The interface cable between the scale and the indicator must be protected against crushing, cutting, or moisture
damage. Protect the cable by running it in conduit. Do not allow the cable to lay in water.
For proper operation, the scale must be level within a 1/4". Choose a site where the floor is close to this standard to avoid
excessive shimming, or modify the floor at the chosen site to meet this standard. After a site is selected:
1. Use hook-end chains to move the scale base to its permanent location. Location should be level and have a solid and
stable foundation. An unstable location causes inaccurate or fluctuating weight readings.
2. Verify that the scale base rests firmly on the floor on all four corner gussets. Shim between each gusset and floor as
required to attain a firm and stable mounting.
3. Anchor to floor if desired (1/2" anchor bolts not included).
Figure 2-3. Anchor RoughDeck FXB Scale to Floor
Gripper plate
bolt