Rice Lake RL-MPS Operation Instructions Manual Download Page 8

4

Mechanical Physician Scale Installation and Operation Instructions

2.2

Steelyard Rod Connection

The steelyard rod is located inside the scale pillar. Once the pillar is attached to the scale base, the steelyard rod 
must be attached to the bottom of the scale. 

1.  Lay the scale on a table as shown in Figure 2-5.

Figure 2-5. Lay Scale on Table to Access Bottom of Scale

2. There are tie wrap wires that prevent the underside of the scale carriage from shifting during shipping. 

Remove and discard the wires on the levers as shown in Figure 2-5.

3. Insert the wrench (included) to the small hole in front of the steelyard rod, and pull the hook of the 

steelyard rod with the hook of the wrench to connect it to the scale base as shown in Figure 2-6.

Figure 2-6. Connecting the Steelyard Rod to the Scale Base

4. Push the long lever frontward, then hook the bearing of the steelyard rod on the pivot of the long lever.  

NOTE:

 Visually ensure that the force lever assembly linkage is centered and properly aligned. Occasionally during 

shipping, the alignment will become skewed however a plug is installed to ensure that the linkage stays aligned. The 
linkage must be free floating in order for the scale to weigh properly. The linkage can be seen by looking up underneath 

Summary of Contents for RL-MPS

Page 1: ...102696 Rice Lake Mechanical Physician Scale Model RL MPS RL MPS 10 RS MPS 20 Operation Instructions...

Page 2: ......

Page 3: ...ent 7 4 0 Troubleshooting 8 5 0 Specifications 8 Technical training seminars are available through Rice Lake Weighing Systems Course descriptions and dates can be viewed at www ricelake com or obtaine...

Page 4: ...chanical Physician Installation and Operation Instructions Rice Lake continually offers web based video training on a growing selection of product related topics at no cost Visit www ricelake com webi...

Page 5: ...uminum height rod and rear wheels These installation and operating instructions will guide the user through basic instructions on pillar assembly wheel installation pillar height rod installation and...

Page 6: ...llar Installation Prior to assembly you ll need the following tools to finish assembling the Mechanical Physician Scale Phillips head screwdriver Wrench included The pillar comes separate from the sca...

Page 7: ...sembly ensuring that the RLWS logo located on the weight beam faces the scale base Figure 2 3 Attach the Pillar to the Scale Base 4 Using a phillips head screwdriver screw in the eight bolts and washe...

Page 8: ...in Figure 2 5 3 Insert the wrench included to the small hole in front of the steelyard rod and pull the hook of the steelyard rod with the hook of the wrench to connect it to the scale base as shown i...

Page 9: ...tructions 5 the top weigh beam if the scale is slightly tipped to one side Figure 2 7 View Looking up at Linkage up Underneath the Top Weigh Beam 5 Place the scale gently back on the floor Force lever...

Page 10: ...slotted holes of the height rod into the two bolts on the front side of the pillar as shown in Figure 2 8 One is located at the top of the pillar and the other towards the bottom of the pillar Figure...

Page 11: ...he wheels upside down can create scale errors 1 Align the angle iron of the wheel base to the scale platform as shown in Figure 2 9 Figure 2 9 Attach the Scale Wheels onto the Scale Base 2 Use the scr...

Page 12: ...olding the scale pointer with your finger until it touches the bottom of the eye loop area Release the scale pointer and let it rise freely up and down between the eye loop area until the scale pointe...

Page 13: ...and properly aligned Occasionally during shipping the alignment will become skewed The linkage must be free floating in order for the scale to weigh properly The linkage can be seen by looking up und...

Page 14: ...0 p m Monday through Friday and 8 a m to 12 noon on Saturday CST Telephone Sales Technical Support 800 472 6703 Canadian and Mexican Customers 800 321 6703 International 715 234 9171 Fax Fax Number 71...

Page 15: ...quipment has not been modified altered or changed by any person other than RLWS or its duly authorized repair agents RLWS will have a reasonable time to repair or replace the defective equipment Buyer...

Page 16: ...12 Mechanical Physician Scale Installation and Operation Instructions...

Page 17: ......

Page 18: ...PN 102696 11 12...

Reviews: