background image

Mechanical Physician Scale Installation and Operation Instructions - Specifications

11

Mechanical Physician Scale Limited Warranty

Rice Lake Weighing Systems warrants that all RLWS equipment and systems properly installed by a Distributor 
or Original Equipment Manufacturer (OEM) will operate per written specifications as confirmed by the 
Distributor/OEM and accepted by RLWS. All systems and components are warranted against defects in materials 
and workmanship for two years. 

RLWS warrants that the equipment sold hereunder will conform to the current written specifications authorized 
by RLWS. RLWS warrants the equipment against faulty workmanship and defective materials. If any equipment 
fails to conform to these warranties, RLWS will, at its option, repair or replace such goods returned within the 
warranty period subject to the following conditions:

Upon discovery by Buyer of such nonconformity, RLWS will be given prompt written notice with a 
detailed explanation of the alleged deficiencies.

Examination of such equipment by RLWS confirms that the nonconformity actually exists, and was 
not RLWS shall be the sole judge of all alleged non-conformities.

Such equipment has not been modified, altered, or changed by any person other than RLWS or its 
duly authorized repair agents.

RLWS will have a reasonable time to repair or replace the defective equipment. Buyer is responsible 
for shipping charges both ways.

In no event will RLWS be responsible for travel time or on-location repairs, including assembly or 
disassembly of equipment, nor will RLWS be liable for the cost of any repairs made by others.

T

HESE

 

WARRANTIES

 

EXCLUDE

 

ALL

 

OTHER

 

WARRANTIES

EXPRESSED

 

OR

 

IMPLIED

INCLUDING

 

WITHOUT

 

LIMITATION

 

WARRANTIES

 

OF

 

MERCHANTABILITY

 

OR

 

FITNESS

 

FOR

 

A

 

PARTICULAR

 

PURPOSE

. N

EITHER

 

RLWS 

NOR

 

DISTRIBUTOR

 

WILL

IN

 

ANY

 

EVENT

BE

 

LIABLE

 

FOR

 

INCIDENTAL

 

OR

 

CONSEQUENTIAL

 

DAMAGES

RLWS 

AND

 

BUYER

 

AGREE

 

THAT

 RLWS’S 

SOLE

 

AND

 

EXCLUSIVE

 

LIABILITY

 

HEREUNDER

 

IS

 

LIMITED

 

TO

 

REPAIR

 

OR

 

REPLACEMENT

 

OF

 

SUCH

 

GOODS

. I

N

 

ACCEPTING

 

THIS

 

WARRANTY

THE

 

BUYER

 

WAIVES

 

ANY

 

AND

 

ALL

 

OTHER

 

CLAIMS

 

TO

 

WARRANTY

.

S

HOULD

 

THE

 

SELLER

 

BE

 

OTHER

 

THAN

 RLWS, 

THE

 

BUYER

 

AGREES

 

TO

 

LOOK

 

ONLY

 

TO

 

THE

 

SELLER

 

FOR

 

WARRANTY

 

CLAIMS

.

N

O

 

TERMS

CONDITIONS

UNDERSTANDING

OR

 

AGREEMENTS

 

PURPORTING

 

TO

 

MODIFY

 

THE

 

TERMS

 

OF

 

THIS

 

WARRANTY

 

SHALL

 

HAVE

 

ANY

 

LEGAL

 

EFFECT

 

UNLESS

 

MADE

 

IN

 

WRITING

 

AND

 

SIGNED

 

BY

 

A

 

CORPORATE

 

OFFICER

 

OF

 RLWS 

AND

 

THE

 B

UYER

.

 © 2012 Rice Lake Weighing Systems, Inc. Rice Lake, WI USA. All Rights Reserved.

RICE LAKE WEIGHING SYSTEMS • 230 WEST COLEMAN STREET • RICE LAKE, WISCONSIN 54868 • USA

Summary of Contents for rl-mps-30

Page 1: ...132702 Rice Lake Mechanical Physician Scale w hand post Model RL MPS 30 Operation Instructions ...

Page 2: ......

Page 3: ...tient 9 6 0 Troubleshooting 9 7 0 Specifications 9 Technical training seminars are available through Rice Lake Weighing Systems Course descriptions and dates can be viewed at www ricelake com or obtained by calling 715 234 9171 and asking for the training department 2012 Rice Lake Weighing Systems All rights reserved Specifications subject to change without notice Rice Lake Weighing Systems is an ...

Page 4: ...Rice Lake continually offers web based video training on a growing selection of product related topics at no cost Visit www ricelake com webinars ...

Page 5: ...r through basic instructions on pillar assembly wheel installation pillar height rod installation hand post installation and the zero adjustment of the scale Figure 1 1 Mechanical Physician Scale Parts Breakdown This manual can be viewed and downloaded from the Rice Lake Weighing Systems web site at www ricelake com health Rice Lake Weighing Systems is an ISO 9001 registered company Weigh beam Poi...

Page 6: ...rior to assembly you ll need the following tools to finish assembling the Mechanical Physician Scale Multi purpose tool included Wrench included The pillar comes separate from the scale base and must be attached prior to use Use the following steps to attach the pillar to the scale base 1 Set the scale base on a table or other convenient place 2 Remove the twisty ties off the scale base as shown o...

Page 7: ...e base assembly ensuring that the RLWS logo located on the weight beam faces the scale base Figure 2 3 Attach the Pillar to the Scale Base 4 Using the wrench provided insert and tighten the eight bolts and washers to secure the pillar to scale base Figure 2 4 Attach Eight Bolts and Washers to Secure the Pillar to the Scale Base ...

Page 8: ...ull the hook of the steelyard rod with the hook of the multi purpose tool to connect it to the scale base lever as shown in Figure 2 5 then push the scale base lever towards the pillar head and hook the bearing of the steelyard rod on the pivot of the long lever Visually ensure that the force lever assembly linkage is centered and properly aligned Occasionally during shipping alignment will become...

Page 9: ...ront side of the pillar as shown in Figure 2 7 One is located at the top of the pillar and the other towards the bottom of the pillar Figure 2 7 Attach the Slotted Screw Location onto the Pillar Bolt Location 2 Use the enclosed wrench to tighten the two stainless steel hex head screws but ensure not to over tighten 3 To raise or lower the height rod press the red button at the top of the height ro...

Page 10: ...errors 1 Align the angle iron of the wheel base to the scale platform as shown in Figure 2 9 Figure 2 9 Attach the Scale Wheels onto the Scale Base 2 Use the screws and washers that are included with the scale to fix the wheel to the platform adjusting the angle iron at a level position then tighten screws 3 When moving the scale hold the two side faces of the pillar to keep the front side of the ...

Page 11: ...screws from the scale base and set the screws and washers aside Figure 3 1 Unscrew Hex Head Screws From Scale Platform 2 Position the hand post over the screw holes on the scale platform making sure that the washer is set between the hand post base and the screw Figure 3 2 Position Hand Post 3 Tighten all four hex head screws with the wrench that has been provided Figure 3 3 Tighten Hex Head Screw...

Page 12: ...irmly seated in the notch and the small poise is firmly against the shoulder of the beam 3 Check the eye loop area of the scale to ensure that the scale pointer is equally balanced between the eye loop area Figure 4 1 Eye Loop Area and Zero Adjusting Screw Location 4 If the scale is not balancing properly then the small zero balance weight must be adjusted Turn the zero adjusting screw shown in Fi...

Page 13: ...heck if the beam pointer is touching the side of the eye loop in its range of travel Visually ensure that the linkage is centered and properly aligned Occasionally during shipping the alignment will become skewed The linkage must be free floating in order for the scale to weigh properly The linkage can be seen by looking up underneath the top weigh beam if the scale is slightly tipped to one side ...

Page 14: ...30 p m Monday through Friday and 8 a m to 12 noon on Saturday CST Telephone Sales Technical Support 800 472 6703 Canadian and Mexican Customers 800 321 6703 International 715 234 9171 Fax Fax Number 715 234 6967 Email US sales and product information at prodinfo ricelake com International non US sales and product information at intlsales ricelake com Mailing Address Rice Lake Weighing Systems 230 ...

Page 15: ...equipment has not been modified altered or changed by any person other than RLWS or its duly authorized repair agents RLWS will have a reasonable time to repair or replace the defective equipment Buyer is responsible for shipping charges both ways In no event will RLWS be responsible for travel time or on location repairs including assembly or disassembly of equipment nor will RLWS be liable for t...

Page 16: ...12 Mechanical Physician Scale Installation and Operation Instructions ...

Page 17: ......

Page 18: ...PN 132702 11 12 ...

Reviews: