5
Figure 1-2. Front Panel Setpoint Setup
1.4.8
Display or Change Setpoint Value
To display a setpoint value, enter front panel setup mode. Press
DOWN
or
ENTER
to display
SETPT1
. The
LEFT/
RIGHT
keys toggle through both setpoints if operator accessible. Press
DOWN
or
ENTER
to display
ENABLE
. Use the
LEFT
/
RIGHT
keys to toggle to
VALUE
. Press
DOWN
or
ENTER
to view the value. See Figure 1-2.
Setpoint Value, Band Value and Hysteresis can be accessible from the front panel in the weigh mode.
To change the setpoint value, use the
UP/DOWN
keys to increment/decrement the decimal value of the flashing
digit. Press
ENTER
to move to the decimal point entry.
LEFT/RIGHT
keys adjust the decimal point placement. Press
the
ENTER
key to accept the displayed value and return to the next value or setpoint number prompt. Press the
UP
key until
SETPNT
is displayed. Press the
UP
key once more to exit. See Figure 1-2.
1.4.9
Turn Setpoint On or Off
To turn a setpoint on or off at the front panel, enter front panel setup mode. Press
DOWN
or
ENTER
again to display
SETPT1
.The
LEFT/RIGHT
keys toggle through each setpoint that is operator accessible. Press
DOWN
or
ENTER
and
ENABLE
is displayed. Press
RIGHT
or
LEFT
to turn the setpoint
ON
or
OFF
. Press the
UP
key until
SETPNT
is
displayed. Press
UP
once more to exit.
1.4.10 Print TIcket
1. Wait for standstill annunciator (
).
2. Press the
key to send data to the serial port.
SETPNT
number
V ALUE
number
BNDVAL
number
HYSTER
OFF
ON
ENABLE
SETPT2
Sub Menu
– Press and hold
UNITS
key for three seconds
SETPT1
Same as SETPT 1
T/DATE
DATE
010104
TIME
0000
NOTE
: Only Available when
ACCESS
=
ON
See Figure 3-11 on page 23 and Table 3-7
on page 24 for more information.
NOTE
: The indicator will begin
incrementing time at power up.
Note
Summary of Contents for Revolution SURVIVOR 420HE
Page 55: ......