![Rice Lake REVOLUTION 682 Synergy Plus Technical Manual Download Page 20](http://html1.mh-extra.com/html/rice-lake/revolution-682-synergy-plus/revolution-682-synergy-plus_technical-manual_1453947020.webp)
682 Synergy Plus
12
Visit our website
2.6 Backplate Attachment
Once work inside of the enclosure is complete, reattach the backplate ground wire to the backplate. Position the backplate over
the enclosure and install the ten backplate screws. Use the torque pattern in
to prevent distorting the backplate
gasket. Torque screws to 12 in-lb (1.4 N-m).
Figure 2-11. Backplate Torque Pattern
NOTE: Torqued screws may become less tight as the gasket is compressed during the torque pattern; a second torque is
required using the same pattern and torque value.
2.7 Sealing the Indicator (Optional)
Insert a lead wire seal through three fillister screws. This restricts access of the setup switch, electronics, electrical contacts and
Legal for Trade configuration parameters.
NOTE: The audit jumper (J24) must be set to off to require pressing the setup switch for access to configuration
parameters. See
for the location of the audit jumper on the CPU board.
Figure 2-12. Sealing the Indicator – No Access
1. Reposition the two fillister head backplate screws to the lower right and lower right-center screws locations.
2. Torque the two backplate screws and setup screw as specified in
3. Navigate the sealing wire through the fillister head screws on the backplate and the fillister head screw at the bottom of
the enclosure, as shown in
4. Seal the wire to secure.
1
2
8
6
7
3
4
5
9
10
Summary of Contents for REVOLUTION 682 Synergy Plus
Page 129: ......