EDP Commands
© Rice Lake Weighing Systems
●
All Rights Reserved
45
7.2 Reporting Commands
Reporting commands send specific information to the communications port. The commands listed in
either setup mode or weigh mode.
7.3 Reset Configuration Command
The following command can be used to reset the configuration parameters of the 680.
All scale calibration settings are lost when the RESETCONFIGURATION command is run
.
Kn
This command acts like pressing numbers 0 (zero) through 9
KDOT
This command acts like pressing the decimal point (.)
KENTER
This command acts like pressing the
Enter
key
KYBDLK
In setup mode, this command locks the keys, except for the
Menu
key
KLOCK=x
In setup mode, this command locks specified front panel key; x = KPRINT, KUNITS, KTARE, KGROSSNET, KZERO,
K0-K9, KDOT, KCLEAR (example: to lock the
Zero
key, enter KLOCK=KZERO
KUNLOCK=x
In setup mode, this command unlocks specified front panel key; x = KPRINT, KUNITS, KTARE, KGROSSNET, KZERO,
K0-K9, KDOT, KCLEAR (example: to unlock the
key, enter KUNLOCK=KPRINT
Command
Function
DUMPALL
Returns a list of all parameter values
DUMPAUDIT
Returns the Audit Trail information
KDUMPAUDIT
Returns the Audit Trail information on the same port which the EDP command was sent
AUDIT.LRVERSION
Returns the legally relevant firmware version
AUDIT.CONFIG
Returns the number of times configuration has changed
AUDIT.CALIBRATE
Returns the number of calibrations
AUDITJUMPER
Returns the position of the audit jumper (ON or OFF)
SPDUMP
Returns a list of the setpoint parameter values
VERSION
Returns the firmware version
HARDWARE
Returns the option card installed
HWSUPPORT
Returns the CPU board part number
RTCBATTERYSTATUS
Returns the status of the real time clock battery (GOOD or BAD)
Table 7-2. Reporting Commands
Command
Function
RESETCONFIGURATION
Restores all configuration parameters to default values (setup mode only)
Table 7-3. Reset Configuration Command
Command
Function
Table 7-1. Key Press Commands (Continued)
Note