Rice Lake MSI Dyna-Clamp Operation Manual Download Page 10

MSI Dyna-Clamp Tension Meter

6

Visit our website 

www.RiceLake.com

3.0

Configuration

This section describes parameter settings on the Dyna-Clamp. The Dyna-Clamp is factory calibrated for up to eight wire rope 

diameters. Calibrations may only be performed by Rice Lake Weighing Systems. Please contact Rice Lake Weighing Systems 

for calibration assistance or if additional wire rope calibrations are required.

3.1 General Navigation

Use the following keys for navigating through the menus when setting up the Dyna-Clamp:

• Press 

 to scroll through the parameters or settings

• Press 

 to enter a selected parameter or to save a selection and return to previous menu

• Press 

 to save a setting and return to previous menu or to tension mode (



 displays)

• Press 

 to return to tension mode without saving settings (



 displays)

3.2 Setup Menu

To enter the setup menu, press 

 and 

 at the same time.

Figure 3-1. Setup Menu

Parameter

Description

Func1

Func2

F1 key – configurable to listed parameters; 

ActFun 

(default)

F2 key – configurable to listed parameters; 

Scroll 

(default)

• Off – key is disabled

• Test – runs display and system test (

Section 3.3.2 on page 7

)

• Unit – ability to change between available units lbf, kgf and kN (

Section 3.3.3 on page 7

)

• Print – not currently implemented

• Scroll –

 

scrolls through the available wire rope types and the average and peak values in the secondary (top) display area 

(

Section 3.3.4 on page 7

)

• ActFun – performs action based on the active function that is displayed in the secondary (top) display; adds an additional 

value for average or clears the current peak value (

Section 3.3.5 on page 7

)

A-OFF

Auto-Off – sets the amount of standstill time (in minutes) before the Dyna-Clamp automatically turns off (

Section 3.4 on page 8

)

settings: Off (default), 15, 30, 45, 60

Range

Range – sets a low (Lo) and high (Hi) setpoint value; provides an indication of when the tension measurement is within this 

specified range (

Section 3.5 on page 8

); settings:

• Off – indicates setpoints are disabled

• On – indicates setpoints are enabled

• Lo – prompts user to enter setpoint value for low range setpoint

• Hi – prompts user to enter setpoint value for high range setpoint

Filter

Tension Filter – allows the scale to adjust to situations where there may be movement or vibration (

Section 3.8 on page 10

); 

settings: Off, LO, Hr-1, Hr-2

Unit

Tension Units – sets the units displayed (

Section 3.7 on page 9

); settings: Lb.F (lbf), I G.F (kgf), I N (kN)

b.Life

Battery Life – sets the options for standard or extended battery life (

Section 3.8 on page 10

); settings: Stand, Long

Table 3-1.  Setup Menu Parameter Descriptions

F2

F1

F2

6HWYS

)YQF

IYQF

D2II

UDQJH

/R

+L

ILOWHU

E/LIH

XQLW

$FWI9Q

2II

WHVW
8QLW

SULQW

6FUR//

$FWI9Q

2II

WHVW
8QLW

SULQW

6FUR//

2II




2II

21

value

value

2II

/2

+L

+L 

/EI
,*)

,P

VWDQG

/RQJ

Summary of Contents for MSI Dyna-Clamp

Page 1: ...MSI Dyna Clamp Tension Meter Operation Manual May 19 2020 PN 193853 Rev A...

Page 2: ...marks of their respective companies All information contained within this publication is to the best of our knowledge complete and accurate at the time of publication Rice Lake Weighing Systems reserv...

Page 3: ...sion Measurement 4 2 7 Average Function 5 2 7 1 Average Procedure 5 2 7 2 Clearing Average 5 2 8 Peak Function 5 2 8 1 Clearing Peak 5 2 9 Safety Strap 5 2 10 Carry Case Option 5 3 0 Configuration 6 3...

Page 4: ...na Clamp Tension Meter ii Visit our website www RiceLake com Rice Lake continually offers web based video training on a growing selection of product related topics at no cost Visit www ricelake com we...

Page 5: ...nderstood Failure to follow the instructions or heed the warnings could result in injury or death Contact any Rice Lake Weighing Systems dealer for replacement manuals Failure to heed could result in...

Page 6: ...Battery displays when approximately 10 of battery life remains and blinks when automatic shutdown is imminent 6 Primary display with six 0 7 18 mm numeric digits displays live wire rope tension and is...

Page 7: ...n extended period of time 2 2 Product Dimensions Figure 2 1 Product Diagram 2 3 Power Press to turn on the Dyna Clamp The startup sequence displays all LCD segments followed briefly by the software ve...

Page 8: ...y grease to the drive rod threads to maintain proper lubrication 1 Loosen the drive rod 2 Zero the Dyna Clamp Section 2 5 Figure 2 2 Dyna Clamp On Wire Rope 3 Position the Dyna Clamp on the wire rope...

Page 9: ...Clearing Average Follow this procedure when the running average needs to be cleared 1 Position the Dyna Clamp on the wire rope and tighten slightly so a little positive tension is measured by the dev...

Page 10: ...ls through the available wire rope types and the average and peak values in the secondary top display area Section 3 3 4 on page 7 ActFun performs action based on the active function that is displayed...

Page 11: ...counting from to followed by the c cal value displaying in the secondary display area The test can be single stepped 1 Press F key set to then immediately press to stop the auto scroll 2 Press to scro...

Page 12: ...gh setpoint value then the setpoint 2 LED turns on If the tension measurement is within the specified range then neither setpoint LED is on Use the following steps to set the Range setpoint values 1 P...

Page 13: ...s in the secondary top display area 4 Press to scroll through the available filter settings 5 With desired filter displayed press to accept displays 6 Press to save and return to tension mode 3 7 Unit...

Page 14: ...if it is in the setup menu The auto off parameter Section 3 4 on page 8 also conserves battery life by turning the unit off if no activity is sensed for a set time The standard mode is recommended for...

Page 15: ...before load is lifted Zero the Dyna Clamp with no load attached lbf kgf kN units causing confusion Select proper units Requires recalibration Requires authorized service Display reading not stable Exc...

Page 16: ...ls are recharged immediately after Low Battery starts to blink Do not allow the batteries to discharge completely it may compromise the recharge life of the battery NiMH Cells have a lower capacity th...

Page 17: ...4 Bobbin Replacement 1 Remove the bolt securing the wire rope bobbin to the frame and discard old bobbin 2 Align new wire rope bobbin with hole in frame 3 Torque bolt to 30 ft lb 40 N m with blue Loc...

Page 18: ...c digits Secondary Display top Eight 0 5 13 mm numeric digits Function Keys Programmable Keys Two user programmable F1 F2 TEST UNIT PRINT SCROLL ACTFUN Permanent Keys Two fixed POWER ZERO Setpoints Tw...

Page 19: ......

Page 20: ...anada Mexico 800 321 6703 International 715 234 9171 Europe 31 0 26 472 1319 Rice Lake Weighing Systems is an ISO 9001 registered company Rice Lake Weighing Systems Specifications subject to change wi...

Reviews: