Configuration
© Rice Lake Weighing Systems
●
All Rights Reserved
9
3.6 Filter
Change the filter settings to adjust to situations where vibration in the wire rope or the structure. If the reading is not stable, it
can be improved by increasing the filter setting. Settling time is longer when the filter setting is increased. The Dyna-Clamp
uses algorithms that speed up large tension changes while still controlling vibration even with higher filter settings.
Use the following steps to set the Filter parameter:
1. Press
and
simultaneously to enter setup menu.
displays.
2. Press
to scroll to
.
3. Press
. The current setting flashes in the secondary (top) display area.
4. Press
to scroll through the available filter settings.
5. With desired filter displayed, press
to accept.
displays.
6. Press
to save and return to tension mode.
3.7 Units
Units can be changed in two ways. By programming an F-key to
) or by changing the units within
the setup menu using the following procedure:
1. Press
and
simultaneously to enter setup menu.
displays.
2. Press
to scroll to
.
3. Press
. The current setting flashes in the secondary (top) display area.
4. Press
to scroll through the available units.
5. With desired unit displayed, press
to accept.
displays.
6. Press
to save and return to tension mode.
Parameter
Description
Off
Disables filtering function
Lo
Low Filter
Hi-1
High Filter
Hi-2
Very High Filter
Table 3-2. Filter Settings
F2
F2
F1
F2
F1
F2
F2
F1
F2
F1