Rice Lake DIGI DSX-1000 Operation Manual Download Page 29

Maintenance and Troubleshooting

25

9. Press 

ENTER

PASSWORD

. The numeric keypad displays. 

10. Enter the password 009 and press 

. The 

DIGI DSX-1000

 displays a warning that the software version 

will be updated.

OTHERS

WARNING

Figure 5-2. Software Update Warning

11. Press 

 to continue. The 

DIGI DSX-1000

 the following notification displays and the unit is ready 

to upgrade. Pressing 

CA

N

CEL

 returns the unit to the previous menu.

 

OTHERS

WAITING...

Figure 5-3. DIGI DSX-1000 in Upgrade Mode

Note

 The DIGI DSX-1000 remains at this display until the unit is power cycled at the end of the upgrade process.

At the PC, the Mini R16 status light changes from red to green.

Figure 5-4. Mini R16 Status

Summary of Contents for DIGI DSX-1000

Page 1: ...DIGI DSX 1000 Checkweigher Version 1 Operation Manual PN 174290...

Page 2: ...marks of their respective companies All information contained within this publication is to the best of our knowledge complete and accurate at the time of publication Rice Lake Weighing Systems reserv...

Page 3: ...3 4 2 Type W Standard Manual 14 3 4 3 Type B Standard Command 15 3 5 Setpoint Interface 15 3 5 1 Specification 15 3 5 2 Pin Assignment 15 3 5 3 Setpoint Signal ON Timing 16 3 5 4 Setpoint Output Cont...

Page 4: ...hooting 23 5 1 Maintenance 23 5 1 1 Cleaning 23 5 2 Troubleshooting 23 5 3 Software Upgrade 24 6 0 Specifications 28 Rice Lake continually offers web based video training on a growing selection of pro...

Page 5: ...ult in damage to equipment or corruption to and loss of data General Safety WARNING Do not operate or work on this equipment unless this manual has been read and all instructions are understood Failur...

Page 6: ...2 DIGI DSX 1000 Operation Manual 1 2 Dimensions 11 5 291 mm 10 7 270 9 mm 13 9 351 9 mm 7 8 198 4 mm 3 8 97 1 mm Figure 1 1 Dimensions DIGI DSX 1000...

Page 7: ...ctor A D Convertor LCD Load Cell Set Point Interface RS 232 Interface Micro Controller R5F100G Figure 1 2 Electrical Connections CN1 LCD CN4 Printer CN5 RS 232 CN3 Set Point A D Convertor CN6 Load Cel...

Page 8: ...g 0 0001 lb 1e 25IR 299 95 g 0 75 lb 6 kg 15 lb 2 g 0 005 lb 1e 100IR 2998 g 7 5 lb 6 kg 15 lb 1 g 0 002 lb 1e 50IR 2999 g 7 5 lb 6 kg 15 lb 0 5 g 0 001 lb 1e 25IR 2999 5 g 7 5 lb 15 kg 30 lb 5 g 0 01...

Page 9: ...ays when the current zero point is at or within 0 25 d of true zero See Section 4 1 on page 17 NET displays when a tare weight is set See Section 4 2 on page 17 Tilde displays when the weight on the s...

Page 10: ...t in accumulation See Section 4 5 on page 22 Not used at this time Prints numeric weight data only See Section 4 3 on page 18 Enter mode selection Set a digital tare weight See Section 4 2 2 on page 1...

Page 11: ...COUNT and FULL WEIGHT data are displayed 5 Ensure there is no weight on the scale 6 Press If the zero calibration is good SUCCESS is displayed If FAILED is displayed repeat the procedure Contact Rice...

Page 12: ...time on the DIGI DSX 1000 1 Power on the scale 2 Press to enter mode selection 3 Press 4 Press to display the digital keypad 5 Enter date and time in order of YY MM DD HH MM SS Figure 2 2 Enter Date a...

Page 13: ...2 00 1 second 01 3 second 10 5 second 11 10 second Transmission condition of RS232 C Bit 1 0 Weight Stable 1 Unconditional Additional parity code in text of RS 232C Bit 0 0 No 1 Yes 4 Tare Weight in t...

Page 14: ...2 1 000 No point 001 0 0 010 0 00 011 0 000 100 0 0000 101 0 00000 Type of Decimal point Bit 0 0 Standard 1 Europe 23 Manual Tare Cancellation Bit 3 0 Allow 1 Inhibit Tare Subtraction Bit 2 0 Allow 1...

Page 15: ...connected to the scale RTS and CTS do not need to be connected Spec 1 See Section 2 3 on page 9 3 2 Control Code and Characters Table 3 2 Control Code and Characters Control Code Character Description...

Page 16: ...ytes 2 Bytes CR Header Code Tare Weight Weight Unit CR Additional Parity LF 1 Byte 1 Byte 7 Bytes 2 Bytes 1 Byte 1 Byte 1 Byte Table 3 3 Status Flags Status Flag Bit Data Description Not Used Bit 7 No...

Page 17: ...ions must be set to satisfy this condition See Section 2 3 on page 9 Example 3 Weight is overflow data Net weight OF Weight Condition Flag Bit Data Description Not Used Bit 7 Not Used always 0 Fixed t...

Page 18: ...the weight stable check is dependent on the Specification 3 setting 3 4 1 Type A Standard Stream The data is transmitted to the PC continuously PC DSX 1000 Figure 3 1 Type A Standard Stream Communicat...

Page 19: ...and Communication 3 5 Setpoint Interface 3 5 1 Specification Interface Open collector passive type Max Rated Input Voltage 24 VDC Max Rated Current 50 mA External Power VEXT 6 15 VDC 12 VDC Recommende...

Page 20: ...oint value is zero the setpoint signal will not be ON Figure 3 4 Setpoint Signal ON Timing 3 5 4 Setpoint Output Control By using additional external circuitry the outputs can be triggered by changes...

Page 21: ...ressed both the manual tare and the digital tare are cleared All manual and digital tare values are lost when the instrument is powered off 4 2 1 Manual Tare 1 Power the scale on and wait for the scal...

Page 22: ...ys If the weight is out of the available range of tare reduction the weight remains on the display and an alarm beeps 4 2 3 Clearing a Digital Tare 1 Press to enter the digital tare mode 2 Press TARE...

Page 23: ...t setting menu Figure 4 3 Minimum and Maximum Weight Setting Menu 2 Press to set the minimum weight 3 Press to display the digital key pad Figure 4 4 Setting Minimum Weight 4 Press the numbers on the...

Page 24: ...ight limit set at 1 000 lb and the percent set at 10 the CURRENT MINIMUM displays 0 900 for a minimum weight equal to 0 900 lbs 9 Press to return to the minimum and maximum weight setting menu 10 Pres...

Page 25: ...tor of where the weight on the scale lies in relationship to the minimum and maximum weight limits When weight limits are set this symbol illuminates from left to right as the weight increases on the...

Page 26: ...eighed and the total accumulated weight of the items lb TOTAL WEIGHTem ipsum TIMES 4 TOTAL 8 389 lb Figure 4 6 Total Accumulated Weight Menu 5 Press to clear the total accumulated weight 6 Press to re...

Page 27: ...1 Troubleshooting Table for the DIGI DSX 1000 Symptom Possible Cause Corrective Action The display shows 888888 lock up The zero point is out of range Recalibrate the scale The display shows O F A wei...

Page 28: ...m the Rice Lake Weighing Systems website Once the software has been downloaded and installed to the PC it can be found by clicking on the Windows Start button All Programs then Mini R16 in the program...

Page 29: ...Update Warning 11 Press to continue The DIGI DSX 1000 the following notification displays and the unit is ready to upgrade Pressing CANCEL returns the unit to the previous menu OTHERS WAITING Figure...

Page 30: ...tware upgrade file downloaded and saved in Step 1 Figure 5 5 Locate Firmware Upgrade File 13 Press Open A file opened message displays briefly and then the Status display line is blank Figure 5 6 File...

Page 31: ...re upgrade is sent to the DIGI DSX 1000 Once the file transmission is finished a transmission complete notification displays Figure 5 8 Files Transmission Menu and Transmission Complete Display 16 Pre...

Page 32: ...nce Range 0 0 5 mV L C Applied Voltage DC 5 V Speed of A D 10 times per second Conversion Internal Resolution 300 000 Enclosure Dimensions 13 85 in x 9 88 in x 3 82 in 351 9 mm x 251mm x 97 1 mm Exter...

Page 33: ......

Page 34: ...4868 USA U S 800 472 6703 Canada Mexico 800 321 6703 International 715 234 9171 Europe 31 0 26 472 1319 Rice Lake Weighing Systems is an ISO 9001 registered company Rice Lake Weighing Systems Speci ca...

Reviews: