6.
2
Weight and Measurement Specification Settings
Span Switch must be enabled when accessing this mode.
SPEC Option
Description
600
Scale unit specification
0
gram
1
kilogram
601
Display resolution
0
1/10,000
1
1/5,000
2
1/2,500
602
Internal Count
0
500,000
1
1,000,000
603
Minimum display (increment) for Scale A
0
2
1
1
2
5
3
10
604
Weight decimal point for Scale A
0
0
1
0.0
2
0.00
3
0.000
4
0.0000
605
Load cell sensitivity selection (mV/V) for Scale A
0
4.00 mV/V
1
3.76 mV/V
2
3.52 mV/V
3
3.28 mV/V
4
3.04 mV/V
5
2.80 mV/V
6
2.56 mV/V
7
2.32 mV/V
8
2.08 mV/V
9
1.84 mV/V
10
1.60 mV/V
11
1.36 mV/V
12
1.12 mV/V
13
0.88 mV/V
14
0.64 mV/V
15
0.40 mV/V
606
Load cell type for Scale-1
0
500g/5kg twin load cell
1
2.5g/25 kg twin load cell
Table 6-2. Weight and Measurement Specification Settings
Note
Specification Settings