7.2 Reporting Commands
Reporting commands return specific information to the communications port. The commands listed in
either setup mode or weigh mode.
7.3 Reset Configuration Command
The following command can be used to reset the configuration parameters of the 380.
All scale calibration settings are lost when the RESETCONFIGURATION command is run
.
7.4 Parameter Setting Commands
Parameter setting commands allow the current value for a configuration parameter to be displayed or changed.
Current configuration parameter settings can be displayed in setup mode or weigh mode using the following syntax:
command<ENTER>
Most parameter values can be changed in setup mode only.
Use the following command syntax when changing parameter values: command=value<ENTER>. Use no spaces before or
after the equal (=) sign. If an incorrect command is typed or an invalid value is specified, the indicator returns
??
followed by the
error message.
Example: to set the motion band parameter on Scale #1 to 5 divisions, type the following:
SC.MOTBAND#1=5<ENTER>
To return a list of the available values for parameters, enter the command and equal sign, followed by a question mark
(command=?<ENTER>). The indicator must be in setup mode to use this function.
After changes are made to configuration parameters using EDP commands, use the
KSAVE
or
KSAVEEXIT
commands to
commit the changes to memory.
Command
Function
DUMPALL
Returns a list of all parameter values
AUDIT.LRVERSION
Returns the legally relevant firmware version
VERSION
Returns the firmware version
BUILD
Returns the firmware version and build number
HWSUPPORT
Returns the CPU board part number
HARDWARE
Returns C1 if the RTC Option is installed, or FF if no option is installed
Table 7-2. Reporting Commands
Command
Function
RESETCONFIGURATION
Restores all configuration parameters to default values (setup mode only)
Table 7-3. Reset Configuration Command
Command
Description
Values
SC.CAPACITY#n
Scale capacity
0.000001–999999.0,
10000.0
(default)
SC.ZTRKBND#n
Zero track band (in display divisions)
0.0–100.0,
0.0
(default)
SC.ZRANGE#
n
Zero range in % of Full Scale (capacity)
0.0–100.0,
1.9
(default)
SC.INITIALZERO#
n
Initial Zero range in % of full scale
0.0–100.0,
0.0
(default)
SC.MOTBAND#
n
Motion band (in display divisions)
0–100,
1
(default)
SC.SSTIME#
n
Standstill time (in 0.1 second intervals; 10 = 1 second) 0–600,
10
(default)
SC.OVERLOAD#
n
Overload
FS+2%
(default), FS+1D, FS+9D, FS
SC.MAX_WEIGHT#n
Maximum weighment (read only)
-999999–999999
SC.NUMWEIGH#n
Number of weighments (read only)
0–4294967295
For commands ending with
#n
, n is the scale number (1)
Table 7-4. Scales Commands