background image

1280 Enterprise Series™

Color Touchscreen Indicator

Operation Manual

PN 166046

Summary of Contents for 1280 Enterprise Series

Page 1: ...1280 Enterprise Series Color Touchscreen Indicator Operation Manual PN 166046 ...

Page 2: ......

Page 3: ...ftkey Operations 10 1 11 Applications 11 1 11 1 Checkweigher Application 11 1 11 2 Counting Application 12 1 11 3 Recipe Batching Application 13 1 11 4 Truck In Out Application 14 2 0 Specifications 17 Technical training seminars are available through Rice Lake Weighing Systems Course descriptions and dates can be viewed at www ricelake com training or obtained by calling 715 234 9171 and asking f...

Page 4: ...ii 1280 Enterprise Series Rice Lake continually offers web based video training on a growing selection of product related topics at no cost Visit www ricelake com webinars ...

Page 5: ...tion card Two communication ports that support RS 232 RS 485 and RS 422 Two USB host ports One USB device port AC or DC power options Ethernet wired and wireless Other Features Configurable print formats can be defined for up to 1000 characters each These formats are used to print gross or net weights setpoint weights accumulator weights and header information Additional print formats can be creat...

Page 6: ...re to follow the instructions or heed the warnings could result in injury or death Contact any Rice Lake Weighing Systems dealer for replacement manuals Proper care is your responsibility Failure to heed may result in serious injury or death Some procedures described in this manual require work inside the indicator enclosure These procedures are to be performed by qualified service personnel only ...

Page 7: ...Network Information Screen which includes information on Wired Ethernet Wi Fi and Bluetooth 6 Current scale Scale number currently displayed 7 Gross Net Current weighing mode 8 Standstill icon Indicates scale is stable 9 Tare Weight of tare in system 10 Weight reading for current scale 11 Unit of measure 12 Capacity and division size values shown are for illustration only 13 Application area Conta...

Page 8: ...ed with a numeric keypad as shown in Figure 1 4 on page 5 2 1 3 4 Figure 1 2 1280 On screen Full Keyboard for Alphanumeric Entry 2 1 3 4 Figure 1 3 1280 On screen Numeric Keypad for Numeric Entry Table 1 2 On screen Keyboard Descriptions Item No Description 1 Cancel Press to exit keyboard 2 Done Press to complete keyboard entry 3 Clear Delete everything in the prompt line 4 Backspace Delete one ch...

Page 9: ...ntering numbers letters Press ENTER to save entries from the numeric keypad 1 4 3 Toggle Gross Net Mode Pressing toggles the display mode between gross and net If a tared value is in the system Net is displayed net equals gross minus tare If there is no tare in the system Gross is displayed 1 4 4 Toggle Units Pressing toggles between primary secondary and tertiary units 1 4 5 Zero Scale Use the fo...

Page 10: ...he system 1 4 7 Print Ticket Pressing sends the gross or net ticket format to the configured serial USB or Ethernet port associated with its ticket format When displaying the accumulator it prints the accumulator format To print tickets using auxiliary formats 1 20 enter the format number with the numeric keypad 1 Wait for to display 2 Enter an auxiliary format 1 20 3 Press to send data to the ser...

Page 11: ...ters See the 1280 Technical Manual Calibration Allows calibration of the scale See the 1280 Technical Manual Setpoint Values Allows setup of setpoint values See the 1280 Technical Manual Audit Trail Provides tracking information for configuration and calibration events See Section 1 5 1 Language Allows one of 16 languages to be selected for the indicator display See Section 1 5 2 Return Arrow Pres...

Page 12: ... configuration or calibration changes are counted as change events restoration of the previous saved configuration or calibration is also counted Select to view the legally relevant version the configuration counters and the calibration counters Figure 1 6 Audit Trail Screen 1 Press to send the audit trail data out the configured communications port default is port 1 See the 1280 Technical Manual ...

Page 13: ...e arrows to scroll to the record needed 3 To print the currently selected record press Reprint 4 Repeat steps 1 3 until all records required have been printed 5 When all records required have been printed press Done For more information see the 1280 Technical Manual 1 7 Peak Hold Peak hold is used to determine display and print the greatest weight reading during a weighing cycle There are three ty...

Page 14: ...llows time and date change Display Tare Displays a tare value for the current scale Display Accum Displays an accumulator value if enabled for the current scale Display ROC Displays a rate of change value if enabled for the current scale Setpoint Displays a list of configured setpoints allows change to target and enable parameters Batch Start Starts a configured batch Batch Stop Stops a running ba...

Page 15: ...e ID low and high weights are displayed and the system waits for the threshold to be triggered Checkweigh 1 When the weight exceeds the threshold weight the indicator checks that an ID was selected If an ID has not be selected the system does nothing If an ID has been selected the system waits for standstill and compares the gross or net weight whichever mode Scale 1 is currently in against the lo...

Page 16: ...p the softkeys Sample Size Scale Select APW Clear Tare and Setup Menu are available Select Sample Size 1 Press the Sample Size softkey The sample size will toggle to five pieces If pressed again it will toggle to 10 pieces then 20 then 50 then 100 then 200 then back to five 2 Press Sample Size once to enter Sample Size Mode Press a numeric key followed by the Enter key to enter any number as the s...

Page 17: ...ARNING Note The Emergency Stop Switch is sold separately See the 1280 Technical Manual for batching switch wiring instructions To restart a batch at a paused step turn the Emergency Stop switch on and use the Abort Run Start switch To abort and exit the batching sequence during a paused batch turn the Emergency Stop switch off and use the Abort Run Start switch To prevent personal injury and equip...

Page 18: ...Database Setup Delete Ingredients Allows an operator to delete ingredients from the ingredient database table Add Edit Recipes Database Setup Add Edit Recipes Allows an operator to add edit recipes from the recipe database table Delete Recipe Database Setup Delete Recipes Allows an operator to delete recipes from the recipe database table Empty Weight 5 0 lb Empty Weight Minimum amount of weight t...

Page 19: ...ored tares parameter is disabled in the Setup menu and will do value swapping if value swapping is enabled in the Setup menu Exit the scale when the light turns green ID 555 GROSS 100000 lb TARE 6000 lb RECALLED NET 94000 lb 1 1 2015 01 05 PM Figure 1 12 Printed Ticket Sample Inbound Trucks 1 Press the Inbound Trucks softkey The system will prompt for a password if one has previously been set for ...

Page 20: ...ed Tares is on the inbound weight is stored even after weighing out When Stored Tares is off the inbound record is deleted after weighing out Inbound Trucks Password Trucks Password Allows an operator to change the password that is required for entry into the inbound truck display If the password is set to nothing the system will not prompt for a password when the Inbound Trucks softkey is pressed...

Page 21: ...annel full duplex RS 232 with CTS RTS RS 485 or RS 422 1200 115 200 baud Digital I O 24 channels configurable as inputs or outputs Inputs 5 VDC max active low Outputs 20 mA max per channel active low 5 VDC source available 500 mA max Relay 4 channel dry contact max current 3A 30 VDC 3A 250VAC Digital I O 8 channels Configurable as inputs or outputs Inputs 5 VDC max active low Outputs 20 mA max per...

Page 22: ...18 1280 Enterprise Series ...

Page 23: ......

Page 24: ...3 Canada Mexico 800 321 6703 International 715 234 9171 Europe 31 0 26 472 1319 www ricelake com www ricelake mx www ricelake eu www ricelake co in Rice Lake Weighing Systems is an ISO 9001 registered company Rice Lake Weighing Systems Specifications subject to change without notice ...