- 44 -
If you have problems with the generator, you can click on "Troubleshooting" and troubleshoot with
the step-by-step guide (see MAINTENANCE, STORAGE AND TROUBLESHOOTING for more
details).
V. OPERATION
This device is a generator intended to be used outdoors. Never use this generator indoors even if
windows or doors are open.
VI.
MAINTENANCE, STORAGE AND TROUBLESHOOTING
Stop and let the engine cool down before any intervention. Make sure the
generator is far from any source of heat. If you are unfamiliar with the
maintenance work, have it done by an authorized dealer.
6.1- General Product Maintenance
Clean plastic parts with a soft clean cloth.
Do not use aggressive cleansers (solvents or abrasive cleansers), abrasive sponge or sharp objects.
Do not put or immerse product in water or any other liquid.
Regular Service Period (4)
Item
Each
use
Every 6
months
or 50 hrs.
Every 1
year or
100 hrs.
Every 2
years or
300 hrs.
Engine oil
Check level
⊙
Change
⊙
(1)
Air cleaner
Clean
⊙
(2)
Spark plug
Check-adjust
⊙
Replace
⊙
Spark arrester
Clean
⊙
Valve Clearance
Check-adjust
⊙
(3)
Combustion
Chamber
Clean
⊙
(3)
Fuel tank & filter
Clean
⊙
Fuel line
Check
⊙
(1) Change engine oil after the first 10 hours of operation.
(2) More frequently if generator used in dusty areas.
(3) These components should be checked by your reseller unless you have the proper tools and are
mechanically proficient.
(4) For commercial use, long hours of operation to determine proper maintenance intervals. Failure
Summary of Contents for 605066