29
29
G
B
POINT A -
ELECTrIC CONNECTIONs
230Vac 50/60Hz POWER SUPPLY (120Vac/60Hz
UPON REQUEST)
BLINKER (40 W MAX.)
MOTOR COMMON CONNECTION
MOTOR PHASES AND CAPACITOR
CONNECTIONS
PEDESTRIAN OPENING CONTACT (NO)
+24Vdc SAFETY STRIP SELF-TEST POWER
SUPPLY
CLOSE LIMIT SWITCH THAT CUTS OFF THE
MOTOR IN CLOSING
LIMIT SWITCH COMMON CONTACT
OPEN LIMIT SWITCH THAT CUTS OFF THE
MOTOR IN OPENING
STOP CONTACT (NC)
OPENING CONTACT (NC)
CLOSING CONTACT (NC)
SINGLE PULSE CONTACT (NO)
ACCESSORIES POWER 24Vdc
ACCESSORIES POWER SUPPLY -24Vdc
GATE OPEN INDICATOR 24Vdc
COMMON CONTACT (common line for all the
command and safety inputs)
SAFETY STRIP CONTACT (NC)
RADIO ANTENNA
COMMON CONTACT (common line for all the
command and safety inputs)
PHOTOCELLS CONTACT (NC)
TEMPERATURE SENSOR CABLE CONNECTION
PROBE (Code ACG4665 optional)
ENCODER CONNECTION (K PLUS operators)
CONNECTOR FOR EXTERNAL RADIO RECEIVER
24Vdc
PROGRAMMING BUTTON
ELECTRONIC REGULATOR FOR LOW SPEED ON
APPROACH
ELECTRONIC TORQUE REGULATOR
DO NOT rEMOVE THE JUMPEr!
OTHErWIsE THE OPErATOr WILL NOT WOrK!
DIP-SWITCHES
J1
J2
J3
J4
J5
J6
J7
J8
s3
Tr1
Tr2
sW s1
sW1
sW2
sW3
L1 - N
U
V-W
PED.
A+ TEST
LSC
COM
LSO
STOP
OPEN
CLOSE
K. BUTT.
A+
A-
SIGNAL
COM
EDGE NC
AERIAL
COM
PHOTO NC
PROBE
ENCODER
RADIO
PROG.
LOW SPEED
TORQUE
SW S1
NC: NORMALLY CLOSED CONTACT
NO: NORMALLY OPEN CONTACT
s1 code BC07096
J5
J7
J6
s3
J8
sW1
sW2
sW3
J4
J3
J2
J1
Tr1
Tr2
sW s1