background image

NOVA

ITALIANO pag. 02 / ENGLISH pag. 06

cod. ACG8046

FOTOCELLULE - PHOTOCELLULES
PHOTOCELLS - FOTOZELLEN - FOTOCÉLULAS

Summary of Contents for NOVA ACG8046

Page 1: ...NOVA ITALIANO pag 02 ENGLISH pag 06 cod ACG8046 FOTOCELLULE PHOTOCELLULES PHOTOCELLS FOTOZELLEN FOTOCÉLULAS ...

Page 2: ...ntatto normalmente chiuso NC PHOT NO Contatto normalmente aperto NO SW2 Microinterruttori di sincronismo DLRX Led rosso per segnalare la corretta alimentazione e l allineamento del segnale infrarosso RIFERIMENTI NORMATIVI PER PORTE E CANCELLI AUTOMATICI L installatore deve assicurarsi che l installazione delle fotocellule NOVA sia fatta solo in presenza di una ulteriore protezione principale come ...

Page 3: ...mento delle fotocellule fare riferimento al manuale di installazione dell operatore o comunque alla norma EN12445 CPL1311 CPL1312 BC08046R BC08046T CPL1940 Contatto N C da collegare ai morsetti COM PHOT Alimentazione 12 24V ac dc da collegare ai morsetti AD AD presenti sulle schede RIB ATTENZIONE Se il led del ricevitore rimane acceso o lampeggia è possibile che siano presenti dei disturbi sulla r...

Page 4: ... sui trasmettitori presenti nell impianto tra di loro come da schema in modo da generare il sincronismo TX3 RX3 TX2 RX2 TX1 RX1 TX4 RX4 NOTA per una corretta sincronizzazione almeno una coppia di fotocellule deve avere entrambi i dip switch in OFF vedi TX1 e RX1 In caso di alimentazione a 12 24 Vac eseguire i collegamenti come da schema ATTENZIONE se si invertono le alimentazioni anche su un solo ...

Page 5: ...enere il led rosso acceso fisso Se il trasmettitore ed il ricevitore sono montati ad una distanza inferiore a 10 metri consigliamo di posizionare il ponticello JP1 come indicato nel paragrafo PORTATA Montare gli schermi protettivi VERIFICA DEL FUNZIONAMENTO FUNZIONAMENTO CON SINCRONISMO Interporre un ostacolo davanti al trasmettitore Verificare che il led rosso del corrispondente ricevitore si spe...

Page 6: ...rmally closed NC PHOT NO Contact normally open NO SW2 Micro switches for synchronization DLRX Red LED indicating correct power and infrared signal power REFERENCE TO STANDARDS FOR AUTOMATIC GATES AND DOORS The installer must ensure that the installation of the NOVA photocells is performed only in the presence of further protection as specified by standard EN12453 in 5 5 1 general protection requir...

Page 7: ...in line with each other For the correct positioning of the photocells refer to the user installation manual or to standard EN12445 CPL1311 CPL1312 BC08046R BC08046T CPL1940 Contact N C to connect to terminals COM PHOT Power 12 24V ac dc to connect to terminals AD AD on the RIB control panels ATTENTION In case the receiver led remains lit malfunctioning of the main supply is suspected It is advisab...

Page 8: ...stem to each other as in the diagram to create synchronization TX3 RX3 TX2 RX2 TX1 RX1 TX4 RX4 NOTE for the correct functioning of the syncronization at least one of the pair of photocells must have both the dip switches in the OFF mode see TX1 and RX1 In case the power supply is 12 24 Vac the wiring must be carried out as per diagram ATTENTION if the power supply is inverted even just on TX or RX...

Page 9: ... adjusted until the red LED is constant If the transmitter and the receiver are mounted at a distance of less than 10 meters from each other we advise positioning the jumper JP1 as indicated in the paragraph RANGE Mount the protective casings SYSTEM CHECK SYNCHRONIZATION Place an object in front of the transmitter Check that the red LED of the corresponding receiver turns off NO SYNCHRONIZATION Pl...

Page 10: ...NOTES 10 10 ...

Page 11: ... avant que l installation ait été déclarée conforme aux dispositions prévues par la Directive This product can not work alone and was designed to be fitted into a system made up of various other elements Hence it falls within Article 6 Paragraph 2 of the EC Directive 2006 42 Machines and following modifications to which respect we point out the ban on its putting into service before being found co...

Page 12: ...segnale radio 20 m Durata batterie 3 anni ACG8037 NOVA WI FI Patent EP10711742 EP2347398 NOVA Wi Fi is the first radio controlled photocell in the world with battery operated transmitter and receiver No wire connections necessary Infrared signal range 25 m Radio signal range 20 m Battery life 3 years ACG8037 NOVA WI FI Patent EP10711742 EP2347398 NOVA Wi Fi es la primera fotocélula del mundo que f...