RIB MEMO ACG7065 Quick Start Manual Download Page 3

MEMO

 

code ACG7065 for SPARK 230-120Vac
code ACG7066 for SPARK 24 Vdc

The MEMO card indicates to the end user when he should call the 
installer for the routine maintenance of the system.

When installing the MEMO card, the installer can determine the 
number of cycles for the automation, by using the micro-switches it 
is provided with. When the automation carries out the given number 
of cycles, a LED of the MEMO card turns on (only if the gate is active) 
and warns you need to carry out the routine maintenance of the 
system.

The 24 Vdc version for direct current operators is provided with a 
second LED (LOW BATTERY), indicating the battery-fed operation 
(LED constantly turned on) and when the battery is discharged 
(blinking LED).

ACTIVATING THE MEMO CARD

1. Clear the system.
2. Remove the blinker cap (fig. 1-2).
3. Insert the card (fig. 3-4).
4.  Select the automatic learning mode «DATA LEARNING» (DIP 1 on 

mode ON) (fig. 5).

5. Energize the system.
6.  Operate one opening and one closing cycle of the gate. While 

opening and closing, the «SERVICE» LED turns on and emits a 
steady light signal for the first 3 seconds, then it blinks indicating 
the storage is in progress. Note: It is important not to stop  the gate 
during the storage process or that safety devices are not activated: 
the procedure shall be therefore carried out carefully.

7.  When the gate is closed, set the «DEMO MODE» (DIP 1-2-3-4 

positioned on OFF) and carry out 2 full operation cycles. During 
the opening of the 3rd cycle, the «SERVICE» LED turns on, thereby 
signaling the correct functioning of the card.

8.  By moving the micro-switches as the card serigraphy indicates, 

enter the number of cycles, after which the system shall warn you 
to carry out the maintenance.

9. Remove the blinker cap (fig. 6).

CHECKING THE CARD FUNCTIONING

You can check the functioning of the MEMO card whenever you want 
to. Just select the «DEMO MODE» and make sure the LED turns on 
(point 7).
WARNING: When the checking procedure is concluded, position the 
micro-switches back where they were, in order to prevent data on 
already stored cycles from being cancelled. At every micro-switch 
change, a RESET of the cycles carried out until that moment takes 
place.
You do not loose stored data if you select the»DEMO MODE».

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Fig. 6

Fig. 5

Fig. 6

G

B

Summary of Contents for MEMO ACG7065

Page 1: ...i 3 secondi si accende fisso poi lampeggia segnalando lo stato di memorizzazione in corso Nota È importante che durante la memorizzazione il cancello non venga fermato o intervengano sicurezze pertanto eseguire la procedura con attenzione 7 A cancello chiuso impostare la modalità DEMO MODE DIP 1 2 3 4 su OFF ed eseguire 2 cicli di funzionamento completi Durante l apertura del 3 ciclo il led SERVIC...

Page 2: ...ite pour signaler l état de mémorisation en cours Remarque Ne pas arrêter le portail lors de la mémorisation et veiller à ce qu aucun dispositif n intervienne lors de cette dernière Par conséquent effectuer la procédure avec attention 7 Lorsque le portail est fermé se servir de la modalité DEMO MODE DIP 1 2 3 4 positionnés sur OFF et effectuer 2 cycles de fonctionnement complets Lors de l ouvertur...

Page 3: ...ts a steady light signal for the first 3 seconds then it blinks indicating the storage is in progress Note It is important not to stop the gate during the storage process or that safety devices are not activated the procedure shall be therefore carried out carefully 7 When the gate is closed set the DEMO MODE DIP 1 2 3 4 positioned on OFF and carry out 2 full operation cycles During the opening of...

Page 4: ...nd der Speicherung nicht anzuhalten oder Sicherheiten einzuschalten daher die Prozedur aufmerksam ausführen 7 Bei geschlossenem Tor die Weise DEMO MODE DIP 1 2 3 4 auf OFF einstellen und zwei komplette Betriebszyklen ausführen Während der Öffnung des 3 Zyklus wird das Led SERVICE aufleuchten und den korrekten Betrieb der Karte melden 8 Indem die Mikroschalter wie auf der Serigrafie gezeigt versetz...

Reviews: