Section I :: User 

12 

I.2.1.4 

Setting the desired temperature 

 

Press the 

TEMP

 keys to increase or decrease the 

required temperature value from a minimum value of 
16°C to a maximum value of 32°C. 

SET

 will appear on 

the screen along with the set temperature value. After a 
few seconds, the sensor temperature reading from the 
control panel will reappear. 

 

I.2.1.5 Fan 

speed 

setting 

 

By pressing the 

FAN

 key several times, it is possible to 

set the speed of the fan between the three available, or 
activate the 

AUTO

 function, which automatically adjusts 

the fan speed depending on the difference between the 
set temperature and the room temperature. 

 

 

Minimum speed 

 

Medium speed 

 

Maximum speed 

 

Automatic control of the speed 
(the symbol flashes). 

I.2.1.6 Lock 

It is possible to block the keyboard on the centralised wired panel by 

pressing the LOCK key for 3 seconds (

 appears): 

- the 

MODE, 

FUN   

 keys are disabled 

- the 

POWER, 

IP

Ÿ

 and 

IP

ź

LIGHT keys stay on. 

To re-enable the keys press LOCK for 3 seconds. 

I.2.1.7 Screen 

back-lighting 

Press the 

Light

 key several times to change the back-lighting of the 

screen, between a maximum and minimum value. 

I.2.1.8 

Unit in alarm condition 

E

x

 

If the unit fails during use it will switch off. The code for 
the triggered alarm will appear on the indicators, the 
alarm code will appear on the centralised wired panel, 

and an audible warning signal will sound (press 

 to 

disable it). 

 

EC 

--- 

communication error 

E2 

Flashing YELLOW 
LED 
two flashes every 
two seconds 

failed air probe 

E3 

Flashing YELLOW 
LED 
three flashes every 
two seconds 

Failed water probe 

E4 

Flashing YELLOW 
LED 
four flashes every 
two seconds 

over-temperature on the heat 
exchanger (maximum limit of 78°C) 

E5 

Flashing YELLOW 
LED 
five flashes every 
two seconds 

the maximum room temperature limit 
has been exceeded (60°C) 

E8 

Flashing YELLOW 
LED 
eight flashes every 
two seconds 

Failed fan motor 

-- 

Flashing RED LED 

dirty air filter (the unit has been used 
for more than 200 h). This is only a 
warning and therefore has no effect 
on unit operation. Press the 
EMERGENCY key for two seconds 
to reset it. 

 
Restore of normal operational conditions of the appliance takes place 
automatically. 
 

I.2.1.9 

Serial connection with centralised wired 
panel (KWPCI) 

Make sure that the DIP4 is on OFF and that the units have an address 
other than 0 (zero). If not, serial communication will not be possible. 

ON

ON

OFF

1   2   3   4  5   6

 

 
To set up the serial connection using the centralised wired panel 
(KWPCI) you will need to assign the addresses: 

-

 Unit 

address: to assign an address to the individual units, you will 

need to use the wired panel (KWPI). Once the wired panel is 
connected to the unit, press the MODE+IP keys at the same time 

for three seconds. 00 will flash, press 

 

 to change the value. 

The address can range between 1÷63. Wait a few seconds for the 
value to save. Repeat the operation on every unit. 

-

 

Centralised wired panel address: press the

IP

Ÿ

 

IP

ź

 keys at the 

same time for three seconds, the address will flash, press the 

IP

Ÿ

 

IP

ź

 keys to change the value. 

The value will be saved after three seconds (the screen displays the 
assigned address, IP02 for example).  

 
It is not advisable to exceed the maximum number of five networked 
centralised wired panels, in supervision. Contact Rhoss spa if you need 
to set up a greater number of wired panels. 
 
It is now possible to decide whether to set one unit at a time, or all of 
them at the same time: 

-

 

Single unit

: choose the address for the unit by pressing the 

IP

Ÿ

 

IP

ź

 keys. The screen displays the current status of the selected 

unit. 
If necessary, change the operating mode. 

-

 

All of the units

: press the 

IP

Ÿ

 key for three seconds. 

The screen displays AL (=ALL) and Pr:ON (=power on) or Pr:Off 
(power OFF) . 
To switch the function off, press the 

IP

Ÿ

 key for three seconds. 

 
 

Summary of Contents for H57984

Page 1: ...V3 21 31 41 Centralised wired panel for terminal units Idrowall I V3 21 31 41 Panneau fil centralis pour les unit s terminales Idrowall I V3 21 31 41 Zentralisierte kabelgebundene Bedientafel f r Inn...

Page 2: ...suppl mentaire sur ses produits dans le cas o les notices fournies s av reraient insuffisantes RHOSS S p A conserve la facult de modifier sans pr avis les caract ristiques de ses produits Mettant en...

Page 3: ...rsonnel about risks that may cause death physical injury or immediate or latent illnesses of any kind DANGER LIVE COMPONENTS The DANGER LIVE COMPONENTS sign warns the operator and maintenance personne...

Page 4: ...arried out by unauthorised personnel or malfunctions caused by the use of non original spare parts or accessories I 2 INSTRUCTIONS FOR USE I 2 1 USING THE CONTROL PANEL 1 Display 2 Keyboard 3 ON OFF b...

Page 5: ...it has been exceeded 60 C E8 Flashing YELLOW LED eight flashes every two seconds Failed fan motor Flashing RED LED dirty air filter the unit has been used for more than 200 h This is only a warning an...

Page 6: ...ite SAFEGUARD THE ENVIRONMENT Dispose of the packaging materials in compliance with the national or local legislation in force in your country DANGER Do not leave the packaging within reach of childre...

Page 7: ...inal on the unit on one side only On the unit side pass the cable through the cable through hole on the machine Access the electrical panel which has a connector installed inside for this connection N...

Page 8: ...Enclosed documents 15 A1 ELECTRICAL CONNECTION DIAGRAM KWPCI N 1 N 2 KRSE DIP4 OFF DIP4 OFF DIP4 OFF KWPCI DIP4 OFF DIP4 OFF DIP4 OFF...

Page 9: ...Section II Installator 16 A2 DIMENSIONS 102 27 114 107 48 5 48 5 10 5 14 19 52 5 25 5 60 17 5 21 111 5 5 8 5 5 5 5 5...

Reviews: