Rhopoint Instruments Novo-Curve Operation Manuals Download Page 3

Novo-Curve Manual 

- 3 - 

Accessories 

 

  Novo-Curve Instrument 

  Traceable calibration tile in protective case 

  Traceability certificate for calibration tile 

  Printed user manual 

  Mini-CD containing Novo-Soft, instrument manuals and 

registration form 

  Registration card 

  USB data cable 

  Footswitch 

  4 x Jigging posts 

  Power supply unit 

  Mains cables (UK, EU and USA) 

 

Options 

  Replacement BAM Traceable calibration tile  

  Supplementary calibration/checking tiles 

  UKAS (ISO17025) BAM traceable calibration/checking tiles 

  Novo-Curve Cylinder Measurement Jig 

 
 

 Power 

 

The Novo-Curve is powered using an external low voltage 
power supply.  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

Summary of Contents for Novo-Curve

Page 1: ...TM Novo Curve TM and Rhopoint TM are either registered trademarks or trademarks of Rhopoint Instrumentation Ltd in the UK and other countries Other product and company names mentioned herein may be t...

Page 2: ...single angle Calibrate all angles Automatic calibration check Statistics Definition of terms used in statistics mode Preferences Changing the calibration value Calibrate at low medium or high gloss Ch...

Page 3: ...ument manuals and registration form Registration card USB data cable Footswitch 4 x Jigging posts Power supply unit Mains cables UK EU and USA Options Replacement BAM Traceable calibration tile Supple...

Page 4: ...unctions View Statistics Press the UP key to view the statistics for the selected angle Delete Press the DOWN key to enter the delete mode Scroll Up Down In the hidden set up menu use the UP DOWN keys...

Page 5: ...ng Press and release the READ SELECT key in measurement mode to take a single reading The value shown in the display is the gloss value for the section of the sample covered by the aperture This value...

Page 6: ...ks or scratches on the lenses the instrument is no longer suitable for measuring gloss and should be returned to an authorised Rhopoint service center Inspecting and cleaning the calibration tile The...

Page 7: ...rror Check Calibration Tile The calibration tile and instrument optics should then be carefully checked for marks or scratches If there are smears mark or dust on the optics press the C key to abort t...

Page 8: ...up arrow Definitions of terms used in statistical mode For this purpose the individual readings are defined as values x1 x2 xn and xi is any data point Statistical sample population n the current num...

Page 9: ...erification of measured values at very high gloss levels The instrument should not be calibrated on a mirror tile Change calibration values in the set up menu Access the hidden set up menu using the f...

Page 10: ...ish Dutch and Italian are the standard languages available in the Novo Curve more languages will be added as they become available visit www rhopointinstruments com for a full list or to request addit...

Page 11: ...ftinstall exe icon in the relevant CD drive Follow the on screen instructions in the install wizard window to install Novo Soft Once installed double click on the Novo Soft icon on the desktop to run...

Page 12: ...Novo Curve Manual 12 Click Install from a list or specific location then click next Click search removable media then click next The PC should find the driver and install it from the disc...

Page 13: ...indow Ensure the instrument is switched on press the read key Press the CONNECT button in the connection window to initiate communication Downloading results Use the download buttons to retrieve store...

Page 14: ...ICE When the instrument has been successfully connected to the PC the auto power off function is disabled Measurements should not be made with the data cable plugged into the instrument as R F interfe...