Connecting the cooler to the Power Supply

Please observe all of the warnings and procedures stated in section 1.1.

Please take care not to pinch or damage the power cord in any way. Please examine 

the power cord for any splits, cuts or damage. If it is unsatisfactory then it must be 

replaced according to the instructions stated in 1.1.

Plug in the cooler and turn on the power. 

Switch on the appliance using the red power switch on the front control panel.

The appliance is designed to run automatically. Defrosting is automatic. The condensate 

water is evaporated automatically by the system.

Maintenance must be performed according to the procedures detailed in section 3 of 

these instructions.

 

2

.

0

  

OPERATION

2

.

1

  

Operation of the Appliance

6

                                                                                                                                                                                                                                                               

Power switch

Light switch

The electronic controller has been factory set to chill the beverages to approximately 

2 Centigrade. Should you wish to alter the set point, please adopt the following procedure;

2

.

2

  

Adjustment of the temperature

Press and hold for 4 seconds to enter the menu.

(DEF) To activate a manual defrost, press this button.

(UP) Increases the parameter value.

(DOWN) Decreases the parameter value.

Step 1: Press and hold the “SET” button for approximately 4 seconds 

Step 2: Press the set button quickly once more and the current set 

point temperature will be displayed.

Step 3: Press the up or down arrow buttons to adjust the setting temperature.

Step 4: Press and hold the SET button for approximately 4 seconds and your

new selection will be stored. If you fail to press SET, the controller will 

time out and revert to the previously stored setting.

WARNING!

Please do not alter the value shown at F2. It must remain at 4 for the cooler to 

invalidate the guarantee.

Summary of Contents for SGT1

Page 1: ...carefully and keep essential maintenance routines Failure to observe the instructions is unsafe and will also invalidate the guarantee the booklet in a safe place for your future reference The booklet contains mandatory safety information as well as WARNING Any refrigeration repair or any electrical work must only be 1 SGT1 SGT2 ...

Page 2: ...ower supply 4 5 1 3 Connecting the cooler to the Power Supply 6 2 0 OPERATION 2 1 Operation of the Appliance 6 2 2 Adjustment of the temperature 6 3 0 MAINTENANCE 3 1 Lighting 7 3 2 Cleaning the interior and exterior 7 3 3 Cleaning the Condenser 7 4 0 IN THE EVENT OF A MALFUNCTION 8 5 0 DISPOSAL AT END OF LIFE 8 6 0 CONTACTS 8 2 ...

Page 3: ...nce Cleaning and user maintenance shall not be made by children without supervision Do not cover the front grille or rear air vents and please observe the installation and setting up instructions described later in this manual Adequate ventilation must be ensured for the appliance Keep clear of obstruction all ventilation openings in the appliance enclosure Do not probe any openings in the cabinet...

Page 4: ...ppliance must always be earthed 1 2 Unpacking and positioning before connecting to the power supply During all operations please be careful not to jolt jar bump or thump the cabinet Handle it gently and with care The refrigeration pipework is delicate and will be damaged by rough handling The appliance is heavy and therefore please carry out a risk assessment prior to beginning this operation Plea...

Page 5: ...nsulted malfunctions may occur including but not limited to the condensate water not draining away and the doors not functioning correctly You may adjust the appliance using the The appliance requires a minimum ventilation space at sides top and rear of 20mm The front grille must be completely unobstructed See Figure 2 Figure 2 accordance with all local laws and regulations Safety Note Please pay ...

Page 6: ...tch Light switch The electronic controller has been factory set to chill the beverages to approximately 2 Centigrade Should you wish to alter the set point please adopt the following procedure 2 2 Adjustment of the temperature Press and hold for 4 seconds to enter the menu DEF To activate a manual defrost press this button UP Increases the parameter value DOWN Decreases the parameter value Step 1 ...

Page 7: ...ng the Condenser This appliance has a low maintenance condenser that is less prone to blockage than other types However it is still recommended to check that it is clean and dust free at least every six months Please adopt the following procedure or go to www cleanme eu for a demonstration enclosure Unplug from the mains power supply Step 2 Looking at the front of the appliance remove the screws f...

Page 8: ...anisation with expertise in the handling of refrigeration appliances For further information please 5 0 DISPOSAL AT END OF LIFE For further information or to obtain Genuine Spare Parts please contact 6 0 CONTACTS to a bar code consult your local Authority 8 condenser condenser Household vacuum cleaner Bar Fridges Australia 40 Production Drive Alfredton www bar fridges australia com au AUSTRALIA WI...

Reviews: