RHINO RCA-2 Operation Instructions Manual Download Page 7

WARNING TO ALL ALARM

INSTALLERS

     The RCA alarm is equipped with Low

Current Negative Pulse Central Lock
outputs. This must not be used unless a
complete understanding of the car’s
central locking system is known. Failure
to do this can damage electronics and
this damage WILL NOT BE
COVERED UNDER WARRANTY! If
unsure, please connect relays as shown
on wiring instructions.

 

 

FOR “NEGATIVE TRIGGER” ORIGINAL POWER LOCK 

SYSTEM

 

          LOCK (ORANGE / BLACK FROM RCA)
                                                                                 TO EXISTING DOOR
                                                                                  RELAYS
          UNLOCK (PINK / YELLOW FROM RCA)

 

 

FOR “POSITIVE PULSE” POWER LOCK SYSTEM 

CONNECT OPTIONAL RELAYS AS SHOWN 

 

               LOCK (ORANGE/BLACK WIRE ON RCA)
                                                                                                 15A FUSE                 +12V

 (PINK YELLOW)            87                           87
             UNLOCK             87a                         87a
                                    86          85           86          85
                                          30                          30

 

LOCK OUTPUT

 

UNLOCK OUTPUT

 

 

TO INSTALL NEW DOOR LOCK MOTORS

  

 CONNECT OPTIONAL RELAYS AS SHOWN 

Summary of Contents for RCA-2

Page 1: ...right button on the transmitter for 1 second NOTE Panic does not work when the ignition is on by requirement of Australian Law EPA L R TO ARM DISARM ALARM Alarm is activated by pressing the button on remote control transmitter The blinkers will flash once and siren will beep once dash LED light will stay on for 20 seconds then flash ALARM IS NOW ON To deactivate alarm press the right button again ...

Page 2: ...mode on the dash LED will flash once and the siren will beep once after the ignition is turned off 2 If you turned the passive arming mode off the dash LED will flash twice and the siren will beep twice after the ignition is turned off When the alarm system initially has power connected to it the passive arm feature will be turned on Please Note If the keyswitch is turned off after the alarm is in...

Page 3: ...r and Ultrasonic Isolation Programmable via Remote Control All Points of Entry Protection Intelligent Pre Warn Shock Impact Sensor Intelligent Shock Impact Sensor Ultra Bright Red Flashing LED Light Electric Boot Release Output via Remote Control Personal Panic Button via Remote Control Visual Arming and Disarming via Blinkers Arming and Disarming Confirmation Beep Door Adjar Warning If a Door is ...

Page 4: ...ted in a vertical position they are less sensitive 3 ALARM TRIGGERS HISTORY MEMORY READ OUT VIA SIREN AND LED To access alarm triggers memory turn ignition on and hood opened i e bonnet switch grounded By pressing the remote control alarm history is indicated via siren and LED 1 Beep 1 Flash Voltage Drop Alarm 2 Beep 2 Flashes Not Used On This Model 3 Beep 3 Flashes Shock Sensor Alarm 4 Beep 4 Fla...

Page 5: ...SONIC GLASS BREAKAGE MICROWAVE DETECTORS OR ETC LIGHT BLUE THIS IS A NEGATIVE TRIGGER AND SHOULD BE CONNECTED TO THE OUTPUT CIRCUIT WIRE ON ANY ACCESSORY TO BE USED ie ULTRASONIC MICROWAVE OR GLASS BREAK DETECTORS ETC BROWN THIS IS THE NEGATIVE OUTPUT 150mA MAXIMUM FOR THE BOOT RELEASE VIOLET BLACK NEGATIVE TRIGGER ON ALARM TO BE USED TO INTERFACE TO PAGER OR OPTIONAL SIREN 100mA MAXIMUM ORANGE BL...

Page 6: ...NEG PULSE 150mA R WHITE DOOR SWITCH NEG TYPES ONLY LIGHT BLUE AUX INPUT NEG TRIGGER VIOLET BLACK NEGATIVE OUT ON ALARM CONNECT THE BLACK 100mA MAX RING TO THE PINK CURRENT SENSE OVERRIDE MOUNTING BOLT EARTH WIRE YELLOW BLACK NEG OUT ON ARM 150mA TO YELLOW BLACK WIRE NEG TO BROWN WIRE NEG OUTPUT FROM RCA OUT ON ARM FROM THE RCA 12V 30A RELAY 15A FUSE IGN 87 86 87A 85 87 30 86 87A 85 CUT WIRE 30 BOO...

Page 7: ...NOT BE COVERED UNDER WARRANTY If unsure please connect relays as shown on wiring instructions FOR NEGATIVE TRIGGER ORIGINAL POWER LOCK SYSTEM LOCK ORANGE BLACK FROM RCA TO EXISTING DOOR RELAYS UNLOCK PINK YELLOW FROM RCA FOR POSITIVE PULSE POWER LOCK SYSTEM CONNECT OPTIONAL RELAYS AS SHOWN LOCK ORANGE BLACK WIRE ON RCA 15A FUSE 12V PINK YELLOW 87 87 UNLOCK 87a 87a 86 85 86 85 30 30 LOCK OUTPUT UNL...

Page 8: ...CK OUTPUT FOR POSITIVE AT REST THEN GOING NEGATIVE OR NEGATIVE AT REST THEN GOING POSITIVE PUT 87 S TO 12V CONNECT OPTIONAL RELAY AS SHOWN LOCK ORANGE BLACK WIRE ON RCA 12V 12V OR GROUND PINK YELLOW 87 87 UNLOCK 87a 87a 86 85 86 85 30 30 12V CAR CAR EXISTING CUT CENTRAL CENTRAL LOCKING LOCKING INTERFACE SWITCH ...

Reviews: