background image

Assembly Instructions

 

Shed House Style 12 x 12 x 8  

The rope channels should be located inside the unit, with 
the frame members passing through the pre-cut slits in 
the end panel/door.  Replace and tighten the carriage 
bolts after putting the end panel into position. 

When putting on the doors, adjust the length to make 
certain the doors do not drape onto the ground.  Adjust 
by pulling more or less material over end arch.  If pulling 
them up puts too much stress on the slit where it goes 
over the wind brace, use a sharp knife to cut slit another 
inch or two to relieve it.  The PE fabric is rip-stop weave 
and will only separate where cut.

 

Step 3.

  Tie off one end of the rope coming out of the 

end panel to a turnbuckle. Turnbuckle should be 
loosened all the way and the open hook end attached to 
the hole in the inside of the end arch.  Hold the end of 
the unsecured rope and apply pressure downward with a 
foot to remove excess.  Re-adjust gathered material 
evenly along door rope.  This step is key to getting a 
good door fit.  Tie off the end off the rope to a second 
turnbuckle attached to a hole in the foot of the end arch 
on the opposite side.  The end panel can be adjusted 
further by tightening the turnbuckles. 

Note: Adjust/Snug the end panel by turning the 

turnbuckles or repeating step 3 on a regular basis 

MAIN COVER INSTALLATION 

Step 1

.  To elongate the life of Main Cover, put a small 

square of duct tape (field supplied) over each bolt head 

V2.2

6

Summary of Contents for SH121208HGN

Page 1: ...damages should be noted on the bill of lading before signing If upon opening the cartons hidden damage is noted contact carrier or its agent immediately Claims for shipping damage MUST be made with the shipping company An inspection of the goods will most likely be required Do not discard packing or any components before the freight company s inspection All claims for freight damage must be made w...

Page 2: ...pright w Foot A End Upright w Foot B Center Side Upright Wind Brace Bent Tube Side Crest Bent Tube Side Crest Bent Tube Side Crest Wind Brace End Upright w Foot A Swedged Cross Rail M F Swedged Cross Rail M F Swedged Cross Rail M F Swedged Cross Rail F F Swedged Cross Rail F F Swedged Cross Rail F F Top Crest Tube Top Crest Tube Top Crest Tube Swedged Cross Rail M F Swedged Cross Rail M F Swedged ...

Page 3: ...cal position Connect 4 SCR 2004 Swedged Cross Rails to the End Arch with 4 CBN 3005 3 carriage bolts washers and nuts through the pre drilled holes in the arch members The Swedged end of the Cross Rails should face the interior of the unit to accept the next cross rail The Cross Rails should be put into the bottom and side hole of the arch upright Again don t tighten the hardware until the next ar...

Page 4: ...en or oval tubing After hardware is tightened insert plastic end plugs 14 2 3 8 15 1 1 8 into all open ends of frame members NOTE Frame must be anchored before installing any doors or cover Each Rhino Shelter 12x12x8 building comes with 4 EARTH CABLE ANCHORS with U bolts and nuts These versatile anchors allow the frame to be secured to almost any surface In addition you have also been provided wit...

Page 5: ...n location of each before installing door ends Step1 Remove Carriage bolts from the Top Crest Rail and the two Upper Cross Rails Install End Panel Door w Zippers DZD 5002 and End Panel with Manway DZD 5003 on desired ends of the Frame assembly Step 2 Place the end panel over the first arch and wrap the material around the arch bringing the slits in the end panel to the inside of the frame arch End...

Page 6: ...te where cut Step 3 Tie off one end of the rope coming out of the end panel to a turnbuckle Turnbuckle should be loosened all the way and the open hook end attached to the hole in the inside of the end arch Hold the end of the unsecured rope and apply pressure downward with a foot to remove excess Re adjust gathered material evenly along door rope This step is key to getting a good door fit Tie of...

Page 7: ...d be out of the rope at this time Repeat this step on both ends of the cover Tighten the turnbuckle to tighten the cover This step may need to be repeated to ensure a snug and centered fit V2 2 7 Step 3 When the cover is completely aligned secure the cover to the bottom tie down cross rail using the rope provided Start at one end and tie off the rope to the cross rail Lace the rope through the gro...

Page 8: ...ain cover adjustment points at the turnbuckle should be checked and tightened as necessary The turnbuckles should be neither completely extended nor taken up so that turnbuckle should be tight when in the mid range of overall adjustment If necessary readjust rope tie off on turnbuckle as needed to tighten or loosen as needed Cleaning cover and doors can be cleaned with a mixture of light detergent...

Reviews: