5 OPERATING INSTRUCTIONS
5.1 Washing and disinfection cycles
5.1.1 Standard cycles / 190
iX
NORMAL
Phase
0
C
Time
ml
Flush, cold water
~5 s
Flush, warm water
~5 s
Circulation wash with detergent
2
min
45
Circulation rinse, hot water
15 s
Disinfection
90
1
min
Approximate total time with heatings
10 min
INTENSIVE
Phase
0
C
Time
ml
Flush, cold water
~5 s
Flush, warm water
~5 s
Circulation wash with detergent
3
min
45
Circulation rinse, hot water
15 s
Disinfection
90
1
min
Approximate total time with heatings
11
min
The following cycle is used for emptying
only
.
The items must be washed and disinfected before taken into use.
EMPTYING
Phase
0
C
Time
ml
Flush, cold water
~5 s
Flush, warm water
~5 s
Approximate total time
1 min
The following cycle can be loaded on the display.
LONG
Phase
0
C
Time
ml
Flush, cold water
~5 s
Flush, warm water
~5 s
Circulation wash with detergent
5
min
45
Circulation rinse, hot water
15 s
Disinfection
90
1
min
Approximate total time with heatings
13 min