5.3 Programming mode
Assuming that a customer has not specified
programming at the factory, the device will be delivered
with the standard default settings as shown in Table 3.
No. Parameter
Default values
Access
3,4 User code
00000
Signal processing
6
Unit*
rpm
7
No. of pulses per unit*
60
8
Input variable*
pnp
20 No. of periods for the average** 15
21 Trigger level signal input**
6,0 [V]
Behavior of the relays
Relay 1
Relay 2
(Optional)
10 Limiting value*
1000,0
3,0
11 Monitoring direction*
↑
↑
12 Direction of contacts for the
state of alarm*
nc
nc
13 Switch back value*
850,0
1,0
18 Switch back time delay**
00.0 [sec]
–
19 Starting-bridge time**
00.0 [sec]
=
Analogue output (optional)
14 Offset*
4 [mA]
15 Scaling factor*
1000 = 20 mA
“No.” pretends the belonging-programming step.
* Standard functions ** special functions
Table 3 Parameters of the device and default values