Rheem Warrior Series AP10414-9 Use And Care Manual Download Page 13

13

If adjustment is necessary…

Turn off the power to the water
heater.

Remove the jacket access panel(s)
and insulation exposing the
thermostat(s).

The thermostat protective cover(s)
should not be removed. 

Using a small screwdriver, set the
thermostat(s) dial pointer(s) to 
the desired temperature.

Replace the insulation and jacket
access panel(s). Turn on the power to
the water heater.

R

E

S

E

T

R

E

S

E

T

TURN OFF

POWER

BEFORE

SERVICING

90

°

F

150

°

F

125

°

F

Type 59T thermostat and
protective cover.

Time/Temperature Relationship in Scalds

Temperature

Time To Produce a Serious Burn

120°F

More than 5 minutes

125°F

1

1

/

2

to 2 minutes

130°F

About 30 seconds

135°F

About 10 seconds

140°F

Less than 5 seconds

145°F

Less than 3 seconds

150°F

About 1

1

/

2

seconds

155°F

About 1 second

Table courtesy of Shriners Burn Institute

DANGER: Hotter water

increases the Potential for Hot
Water SCALDS. Households
with small children, disabled,
or elderly persons may require
a 120°F or lower thermostat
setting to prevent contact with
HOT water.

Water Temperature Setting

The temperature of the water in the water
heater can be regulated by setting the
temperature dial of the adjustable surface
mounted thermostat(s) located behind the
jacket access panel(s). 

Dual element heaters have two
thermostats. 

Safety and energy conservation are factors
to be considered when selecting the water
temperature setting of the water heater’s
thermostat(s). The lower the temperature
setting, the greater the savings in energy
and operating costs.

To comply with safety regulations the
thermostat(s) are factory set at 120°F or
less where local codes require. This is the
recommended starting point.

Water temperatures above 125°F 
can cause severe burns or death from
scalding. Be sure to read and follow the
warnings outlined in this manual and on
the label on the water heater. This label is
located on the water heater near the
thermostat access panel.

Mixing valves are available for reducing
point of use water temperature by mixing
hot and cold water in branch water lines.
Contact a licensed plumber or the local
plumbing authority for further
information.

The chart below may be used as a guide in
determining the proper water temperature
for your home.

Reset button

Thermostat

protective

cover

Thermostat
dial pointer

Summary of Contents for Warrior Series AP10414-9

Page 1: ...nd these instructions or any terms within it seek professional advice Any questions regarding the operation maintenance service or warranty of this water heater should be directed to the seller from whom it was purchased If additional information is required refer to the section on If you need service Do not destroy this manual Please read carefully and keep in a safe place for future reference Re...

Page 2: ...ere You can find them on a label on the appliance Staple sales slip or cancelled check here Proof of the original purchase date is needed to obtain service under the warranty Your safety and the safety of others are very important There are many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol Recognize this sym...

Page 3: ...ructions in how to adjust the thermostat s DANGER Hotter water increases the potential for Hot Water SCALDS D A N G E R HOT Water temperature over 125 F can cause severe burns instantly or death from scalds Children disabled and elderly are at highest risk of being scalded See instruction manual before setting temperature at water heater Feel water before bathing or showering Temperature limiting ...

Page 4: ...e with generic earthquake bracing instructions can be obtained from Office of the State Architect 400 P Street Sacramento CA 95814 or you may call 916 324 5315 or ask a water heater dealer However applicable local codes shall govern installation For residential water heaters of a capacity greater than 52 gallons consult the local building jurisdiction for acceptable bracing procedures READ AND FOL...

Page 5: ...rotected areas Make certain the floor underneath the water heater is strong enough to sufficiently support the weight of the water heater once it is filled with water CAUTION The water heater should not be located in an area where leakage of the tank or connections will result in damage to the area adjacent to it or to lower floors of the structure Where such areas cannot be avoided it is recommen...

Page 6: ...or back flow prevention device is referred to as an open water system As water is heated it expands in volume and creates an increase in the pressure within the water system This action is referred to as thermal expansion In an open water system expanding water which exceeds the capacity of the water heater flows back into the city main where the pressure is easily dissipated A closed water system...

Page 7: ...rd from the valve to allow complete drainage by gravity of the relief valve and discharge line The end of the discharge line should not be threaded or concealed and should be protected from freezing No valve of any type restriction or reducer coupling should be installed in the discharge line To Fill the Water Heater WARNING The tank must be full of water before heater is turned on The water heate...

Page 8: ...cket access panel Shut off valve Jacket access panel Auxiliary catch pan Drain valve Typical Top Connect Installation H O T C O L D E L I E F A L V E Anode To electrical distribution panel Temperature pressure relief valve Electrical junction box use only copper conductors Relief valve discharge line Directed to under side of home Union Hot water outlet to fixtures Heat trap 6 Min Heat trap 6 Min ...

Page 9: ...ically isolated Electrical Connections A separate branch circuit with copper conductors overcurrent protective device and suitable disconnecting means must be provided by a qualified electrician All wiring must conform to local codes or latest edition of National Electrical Code ANSI NFPA 70 The water heater is completely wired to the junction box inside jacket at the top front of the water heater...

Page 10: ...ther unapproved devices other than those authorized by the manufacturer into onto or in conjunction with the water heater The use of unauthorized energy saving devices may shorten the life of the water heater and may endanger life and property The manufacturer disclaims any responsibility for such loss or injury resulting from the use of such unauthorized devices CAUTION If local codes require the...

Page 11: ...permanently damage the dip tube and or heat traps 11 For increased energy efficiency some water heaters have been supplied with a 2 3 8 section of pipe insulation Please install the insulation according to the illustrations above that best meets your requirements Slip the insulation cover over the T P Valve through the center hole and align the hole in the side with the opening of the T P Valve R ...

Page 12: ...w Do not smoke or use an open flame near the faucet at the time it is open CAUTION The cause of the high temperature condition must be investigated by qualified service technician and corrective action must be taken before placing the water heater in service again Safety Controls The water heater is equipped with a combination thermostat and temperature limiting control ECO that is located above t...

Page 13: ...tting The temperature of the water in the water heater can be regulated by setting the temperature dial of the adjustable surface mounted thermostat s located behind the jacket access panel s Dual element heaters have two thermostats Safety and energy conservation are factors to be considered when selecting the water temperature setting of the water heater s thermostat s The lower the temperature ...

Page 14: ... removed from the water heater s tank annually for inspection and replaced when more than 6 of core wire is exposed at either end of the rod Make sure the cold water supply is turned off before removing anode rod NOTICE Do not remove the anode rod from the water heater s tank except for inspection and or replacement as operation with the anode rod removed will shorten the life of the glass lined t...

Page 15: ...fer to the Hydrogen Gas Caution in the Operating Instructions Anode Rod This water heater is equipped with an anode rod designed to prolong the life of the glass lined tank The anode rod is slowly consumed thereby eliminating or minimizing corrosion of the glass lined tank Water sometimes contains a high sulfate and or mineral content and together with cathodic protection process can produce a hyd...

Page 16: ...may be off Make sure electric supply to water heater and disconnect switch if used are in the ON position The thermostat may See the Temperature regulation of the water heater be set set too low section of this manual Leaking or open hot Make sure all faucets are closed water faucets Electric service to your Contact the local electric utility home may be interrupted Improper wiring See the Install...

Page 17: ...ualified service personnel Relief valve Junction box cover Anode rod Hot outlet heat tube on side connect models only Jacket access cover These parts are supplied only on double element models Jacket access cover Thermostat bracket Cavity insulation Upper thermostat Plate cover Relief valve Hot outlet heat trap or dip cup insert on top connect models only Top Connect Models see illustration below ...

Page 18: ...et access panel s and insulation Rotate the crossbar up and down until it breaks away from the remainder of the cavity insert See illustration to the left Discard the crossbar It cannot and need not be replaced Replace the thermostat and or element as necessary Replace the insulation and jacket access panel s before turning on the power to the water heater NOTICE The cavity insert crossbar is nece...

Page 19: ...the Manufacturer s National Service Department at the following address 2600 Gunter Park Drive Montgomery Alabama 36109 1413 Phone 1 800 432 8373 When contacting the manufacturer the following information will be requested a Model and serial number of the water heater as shown on the rating plate attached to the jacket of the heater b Address where the water heater is located and physical location...

Page 20: ...RMOSTAT HIGH TEMP LIMIT ECO 1 2 1 1 2 BLUE CONNECTOR TO OFF PEAK METER TIMER TM2 4 YELLOW YELLOW 2 BRANCH CIRCUIT TO ELECTRICAL DISTRIBUTION PANEL BLACK LOWER HEATING ELEMENT 2 UPPER THERMOSTAT HIGH TEMP LIMIT ECO UPPER HEATING ELEMENT BLUE YELLOW BLACK L1 JUNCTION BOX 4 L2 RED 1 3 1 2 BLACK RED LOWER THERMOSTAT 1 2 4 BRANCH CIRCUIT TO ELECTRICAL DISTRIBUTION PANEL 2 1 2 UPPER THERMOSTAT HIGH TEMP...

Reviews: