33

CALL

Plastic

Plastic

OUT

DESCRIPTION

Green

Cool Dark Gray

B

BURNER TRAY

1-B

Burner Tray w/Burners (Sea Level)*

011578F

011578F

Burner Tray  w/o Burners (Sea Level)*

011579F

011579F

Burner Tray w/Gas Valve Natural MV

011580F

011580F

Burner Tray w/Gas Valve Propane MV

011581F

011581F

Burner Tray w/Gas Valve Natural DSI

011582F

011582F

Burner Tray w/Gas Valve Propane DSI

011583F

011583F

    2-B

Burner Hold Down Kit

011584F

011584F

    3-B

Burner

301210/10

301210/10

    4-B

Burner Orifice Nat. #51  (Sea Level)*

350080F/10

350080F/10

Burner Orifice Pro. #59 (Sea Level)*

350350F/10

350350F/10

C

CONTROLS

1-C

Thermostat Auto Reset 135º Surface Mount

006725F

006725F

2-C

Thermostat Control MV (Mechanical)

003346F

003346F

3-C

Thermostat Control DSI (Solid State)

011585F

011585F

     4-C

PC Board 

005086B

005086B

     5-C

Potentiometer

011586F

011586F

     6-C

Temperature  Sensor

011587F

011587F

G

GAS VALVE

1-G

Combination Valve Nat. MV 

011588F

011588F

Combination Valve Pro. MV 

011589F

011589F

Combination Valve Nat. DSI

011590F

011590F

Combination Valve Pro. DSI

011591F

011591F

H

HEAT EXCHANGER

1-H

Heat Exchange Assy Copper

011592F

011592F

Heat Exchange Assy Cupro Nickel

011593F

011593F

    2-H

Inlet/Outlet Header Complete

011594F

011594F

Inlet/Outlet Header (Includes 6-H)

011595F

011595F

    3-H

Return Header (Includes 6-H)

011596F

011596F

    4-H

Tube Bundle Copper 

**

011597F

011597F

Tube Bundle Cupro Nickel

 **

011598F

011598F

        5-H

Baffle

011599F

011599F

        6-H

Flange Nut Kit

008259F

008259F

        7-H

O Ring Gasket (2)

011600F

011600F

    8-H

Sensor Adapter DSI

006714F

006714F

Sensor Well Millivolt

006805F

006805F

    9-H

Bypass Kit

011601F

011601F

        10-H

Bypass Valve

006716F

006716F

        11- H

Bypass Dam / Shaft

006717F

006717F

        12-H

Bypass Spring 

011602F

011602F

    13-H

Drain Plug

006721F

006721F

    14-H

Inlet/Outlet Header Dam

011603F

011603F

15-H

Hose Adapter 1-1/2" MPT x 1-1/2" Hose (Optional)

011635

011635

16-H

2" CPVC Connector & Nut (2)

006723F

006723F

    17-H

O Ring (2)

006724F

006724F

J

CONTROL BOX

1-J

Control Box DSI  (Includes 3-C)

011604F

011604F

    2-J

Transformer 120/240/24V

011605F

011605F

3-J

Ignition Control Direct Spark

011606F

011606F

4-J

Rocker Switch 

009493F

009493F

*FOR ALTITUDES ABOVE 2,000 FEET ABOVE SEA LEVEL, CONSULT THE FACTORY.

**  

WARNING

: The Hydraulic conditions or water chemistry that caused the tube

bundle to fail have very likely also damaged the bypass valve.  We recommend you inspect
the bypass assembly.  Failure to do so could cause premature failure of this replacement part.

Summary of Contents for Versa Heaters

Page 1: ...To do so may result in an explosion or fire WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your...

Page 2: ...2 Rev 10 reflects the following Changes to Warnings on page 4 Model Identification on page 7...

Page 3: ...ring Diagrams 17 Post Start Up Inspection 20 Cold Weather Operation 20 MAINTENANCE 21 SERVICE 21 Water Pressure Switch 21 Flame Roll Out Safety Switch 22 High Limits 22 Pilot Safety Millivolt Models 2...

Page 4: ...d service must be performed by a qualified installer service agency or the gas supplier WARNING To minimize the possibility of improper operation serious personal injury fire or damage to the heater A...

Page 5: ...your water Automatic Chlorinators Chemical Feeders All chemicals must be introduced and completely dilut ed into the pool or spa water before being circulated through the heater Do not place sanitizin...

Page 6: ...verages before or during spa or hot tub use may cause drowsiness which could lead to unconsciousness and subsequently result in drowning 3 Pregnant Women Beware Soaking in water over 102 F 39 C may ca...

Page 7: ...f the carton is damaged make a note to that effect on the Bill of Lading when signing for the ship ment Remove the heater from the shipping packaging Report any damage to the carrier immedi ately On o...

Page 8: ...open Fig 3 Alternate Method for Providing a Non Combustible Base Clearances less than these may require removal of the heater to service either the heat exchanger or the burner tray In either case the...

Page 9: ...elow or to either side of any opening into the building Refer to the latest revisions of CAN CSA B149 Outdoor High Wind Top High Wind Conditions Outdoor Units Only In areas where high winds are freque...

Page 10: ...the same size as the drafthood outlet is recommended however when the total vent height is at least 10 ft drafthood relief opening to vent terminal the vent pipe size may be reduced as specified in th...

Page 11: ...be used as specified in the latest edition of the National Flue Gas Code ANSI Z223 1 Canada CAN CSA B149 Gas Connections Gas piping must have a sediment trap ahead of the heater gas controls and a ma...

Page 12: ...ure or counter clockwise to decrease pressure Gas Pressure Natural Gas Propane Gas Max Inlet static 10 5 in WC 13 in WC Min Inlet dynamic 7 in WC 11 in WC Manifold Gas dynamic 3 5 in WC 10 in WC Stati...

Page 13: ...3 1 53 Specific Gravity 0 5 in WC Pressure Drop Table E Maximum Equivalent Pipe Length Plumbing from the heater back to the pool or spa must not have any valves or restriction that could prevent flow...

Page 14: ...ow 50 F It also serves to eliminate needless pressure drop through the heater and accompanying reduction in the flow rate to the spa jets etc Bypass Disc Spring Bypass Body Fig 14 Internal Automatic B...

Page 15: ...130A Pressure Drop When installing a remote switch do not exceed 10 ft of wiring from the heater Use 18 gauge stranded wire Electronic Heaters The Direct Spark Ignition Device automatically lights the...

Page 16: ...EN WHITE SUPPLY SIDE Fig 18 240V Hook Up Control Adjustments Millivolt The pool or spa water temperature is controlled by the thermostat on the upper front panel of the heater The control center conta...

Page 17: ...ostat Manual Switch Switch Switch AGS Water Press Gas Valve Roll Out Valve Pilot Generator To Firemans Switch field installed Optional BK BK R Y BK TH PP W R PP TH V BK V BK O O Fig 20 Wiring Diagram...

Page 18: ...ontrol which has been under water 1 STOP Read the safety information above 2 Set the thermostat to the lowest setting 3 Turn off all electrical power to the appliance 4 This appliance is equipped with...

Page 19: ...d from Pilot to Off unless knob is pushed in slightly Do not force 6 Wait 5 minutes to clear out any gas If you then smell gas STOP Follow B in the safety information above If you don t smell gas go t...

Page 20: ...SI Igniter Location Cold Weather Operation Moderate Climate Heater operation can continue during short term cold spells When temperatures are between 0 and 32 F flow continuous pump operation must be...

Page 21: ...trated in the Post Start Up Inspection section In Out Header Drain Plug Fig 25 In Out Header Drain Plug Location Yellow flame means restriction of the air openings Lifting or blowing flame indicates h...

Page 22: ...re switch See Illustrated Parts List for 11 psi water pressure switch CAUTION Do not operate the heater without the function of a properly adjusted water pressure switch or flow switch Fig 27 Flame Ro...

Page 23: ...9 Slide out burner tray 10 Reverse above procedure to reinstall Rear Hold Down Bracket Burner Millivolt Pilot Assembly under Pilot Shield Millivolt Gas Valve Invensys shown Manifold Pilot Lighter Tube...

Page 24: ...burner hold down bracket and spacer can become distorted from direct flame impingement and this usually necessitates replacement of these parts ORIFICES MUST BE PARALLEL WITH BASE TOLERANCE OF 2 0 IGN...

Page 25: ...nstall Tube Cleaning Procedure Establish a regular inspection schedule the frequency depending on the local water conditions and the sever ity of service Do not let the tubes clog up solidly Clean out...

Page 26: ...DO NOT WIRE BRUSH Fig 35 Immersion Well Assembly Replacement Parts Any part returned for replacement under standard company warranties must be properly tagged with a return parts tag completely filled...

Page 27: ...burners Outer jacket very hot Broken refractory caused by paint blistered shipping damage or improper combustion Replace refractory panels Excessive sooting of heat exchanger Determine cause of sooti...

Page 28: ...jumper Replace thermostat Replace high limit that prevented from firing Jump across both TH wires on gas valves Check gas supply gas line size gas pressure Also check for insects or debris in pilot a...

Page 29: ...ive Red Positive 2 Pilot Load 500mV 100 Pilot generator connected to valve Power applied to pilot solenoid TP Thermopile Robertshaw PP Power Pile Honeywell TH TP Common Invensys TH PP Common Honeywell...

Page 30: ...tension wire is properly connected to the igniter Check the gas valve There must be 24VAC while the ignition module is sparking Check the igniter Igniter may not be sensing correctly Check that the s...

Page 31: ...31 ILLUSTRATED PARTS LIST...

Page 32: ...32 5 P 1 P 3 P 4 P 2 P 6 P HONEYWELL MILLIVOLT PILOT 7 P 8 P...

Page 33: ...ange Assy Cupro Nickel 011593F 011593F 2 H Inlet Outlet Header Complete 011594F 011594F Inlet Outlet Header Includes 6 H 011595F 011595F 3 H Return Header Includes 6 H 011596F 011596F 4 H Tube Bundle...

Page 34: ...Pilot Generator MV 600019B 600019B 4 P Pilot Mounting Bracket MV 011610F 011610F 5 P Lighter Tube MV 052797 052797 6 P Pilot Tube MV 004078F 004078F 7 P Ignitor DSI 011611F 011611F 8 P Hi Tension Wire...

Page 35: ...35...

Page 36: ...www raypak com Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 805 278 5468 Litho in U S A...

Reviews: