• Insulation –

sag and moisture proof fiberglass

insulation surrounds the storage tank to mini-
mize heat loss. In addition, heavy mineral wool
insulation surrounds the combustion chamber.

• Anode rods –

patented design utilizes multiple

magnesium rods to ensure long life and corro-
sion resistance.

• Temperature and pressure relief valve –

AGA/ASME rated and factory installed.

• Hand-hole cleanout –

for removal of lime/sedi-

ment deposits.

• Manual reset high limit –

all ASME models are

factory equipped with a manual reset high limit
to meet the code requirements of many states.

• Gas control system –

Fully adjustable

thermostat from 100°F to 180°F, 24 volt
combination gas valve includes main gas
pressure regulation, On-Off manual valve,
120/24 volt transformer, and high limit
temperature cut-out.

• Stainless steel burners –

Precision burners 

of raised port design are formed from high
chromium stainless steel. Entire burner
assembly is built like a drawer which slides 
out easily for quick inspection and simple
maintenance.

• LED dIagnostics –

On damper assembly for

easier service.

Recommended Specifications (for trade reference only)

Water heater(s) shall be 

UNIVERSAL

model ________________, manufactured by RHEEM-RUUD,

having gas input of __________ Btu/hr. and a recovery rate of _____________ GPH at a 100°F tem-
perature rise when tested and certified at ____________ thermal efficiency. Water heater(s) shall have
a storage capacity of _________ gallons. Water heater(s) shall have the CSA seal of certification and
supplied with a factory installed AGA/ASME rated temperature and pressure relief valve. Tank(s) shall
be furnished with a tube bundle having a double coating of high temperature porcelain enamel and fur-
nished with magnesium anode rods rigidly supported. Water heater(s) shall meet or exceed the thermal
efficiency and standby loss requirements of ASHRAE. Tanks shall have a working pressure rating of
150 psi, and shall be completely factory assembled, including a pressure regulator properly adjusted for
operation on ___________ gas with stainless steel burners. Controls will be arranged for safety shutoff
in event of pilot failure. Water heater(s) with inputs less than 360,000 Btu/hr. shall have top, front and
rear side inlet/outlet water connections. Water heater(s) shall be covered by a three year limited
warranty against tank leaks.

• Add for ASME construction –

Water heater(s) shall be constructed in accordance with the requirements of the ASME Boiler and
Pressure Vessel Code, Section IV Part HLW.

Limited Warranty

This product features a three year limited warranty against tank leaks. Please refer to Commercial
Warranty Information brochure for complete warranty information.

C O M M E R C I A L

W A T E R   H E A T E R S

Rheem Water Heating

• 101 Bell Road, Montgomery, Alabama 36117-4305 • www.rheem.com

Rheem Canada Ltd./Ltée

,128 Barton Street West, Hamilton, Ontario L8N 3P3

P R I N T E D   I N   U . S . A

0 5 / 0 6   W P

F O R M   N O . R R 1 0 2 C - 1   R e v. 1 6

In keeping with its policy of continuous progress and product improvement, Rheem-Ruud reserves the right to make changes without notice.

Other Features:

Universal Gas continued.

Summary of Contents for Universal Gas

Page 1: ...igniting the pilot only when the thermostat calls for heat System Sentinel LED diagnostic system our exclusive diagnostic system with glowing LED lights verifies system operation sequence by sequence Full port full flow brass drain valve Certifications and Ratings Efficiency these models have been tested according to ANSI test procedures and meet or exceed the thermal efficiency and standby loss r...

Page 2: ...AL 71 91 111 131 172 232 293 535 778 18 37 7 C LTR 267 344 420 497 650 879 1108 2026 2944 G100 250 A 100 379 250 000 100 F GAL 90 110 131 151 191 252 312 555 797 25 37 7 C LTR 341 418 494 571 724 953 1183 2100 3018 G100 270 A 100 379 270 000 100 F GAL 92 114 135 157 201 266 332 594 855 23 37 7 C LTR 348 430 513 595 761 1008 1256 2247 3238 G72 300 A 72 273 300 000 100 F GAL 75 99 123 147 196 269 34...

Page 3: ... 485 404 346 303 269 242 220 202 186 173 LPH 2294 1835 1529 1311 1147 1020 918 834 765 706 655 G100 270 A 270 000 80 GPH 655 524 436 374 327 291 262 238 218 201 187 LPH 2478 1982 1652 1416 1239 1101 991 901 826 762 708 G72 300 A 300 000 80 GPH 727 582 485 416 364 323 291 264 242 224 208 LPH 2753 2202 1835 1573 1376 1224 1101 1001 918 847 787 G85 300 A 300 000 80 GPH 727 582 485 416 364 323 291 264...

Page 4: ...00 250 A inches 73 1 4 66 1 8 30 1 4 23 1 4 8 57 1 2 3 4 23 1 1 2 2 2 795 lbs 835 lbs mm 1861 1680 768 591 203 1460 19 584 38 51 51 360 kgs 378 kgs G100 270 A inches 73 7 8 66 1 8 30 1 4 23 1 4 8 57 1 2 3 4 23 1 1 2 2 2 805 lbs 845 lbs mm 1876 1680 768 591 203 1460 19 584 38 51 51 365 kgs 383 kgs G72 300 A inches 71 64 1 8 26 1 4 25 8 58 5 8 3 4 20 1 1 2 1 1 2 1 1 2 590 lbs 630 lbs mm 1803 1629 66...

Page 5: ...0 inches mm G37 200 inches mm G76 200 inches mm G91 200 inches mm G100 200 A inches mm G72 250 A inches mm G100 250 A inches mm G100 270 A inches mm G72 300 A inches mm G85 300 A inches mm G100 310 A inches mm G65 360 A inches mm G65 400 A inches mm G85 400 A inches mm G100 400 A inches mm CLEARANCES TO COMBUSTIBLES MODEL NUMBER UNITS SIDE REAR TOP DIMENSIONAL DIAGRAM Allow a minimum of 18 457mm f...

Page 6: ... s shall have the CSA seal of certification and supplied with a factory installed AGA ASME rated temperature and pressure relief valve Tank s shall be furnished with a tube bundle having a double coating of high temperature porcelain enamel and fur nished with magnesium anode rods rigidly supported Water heater s shall meet or exceed the thermal efficiency and standby loss requirements of ASHRAE T...