AP18733 REV. 3.2.17
75
Figure 54 – Flame Sight Glass
DHW Inlet Temperature Sensor (7850P-015) Exhaust Temperature
Sensor (7850P-070)
Temperature (°F/ °C)
Resistance (Ω)
Resistance (Ω)
-4 / -20
28409
5 / -15
22152
14 / -10
17408
23 / -5
13782
32 / 0
10990
41 / 5
8824
50 / 10
7131
59 / 15
5800
68 / 20
4747
77 / 25
3906
86 / 30
3233
95 / 35
2690
104 / 40
2250
113 / 45
1891
122 / 50
1598
131 / 55
1356
140 / 60
1155
149 / 65
989
158 / 70
850
167 / 75
733
176 / 80
635
185 / 85
552
194 / 90
482
203 / 95
421
212 / 100
370
DHW Inlet Temperature Sensor (7850P-015) Exhaust Temperature
Sensor (7850P-070)
Temperature (°F/ °C)
Resistance (Ω)
Resistance (Ω)
-4 / -20
62162
5 / -15
48440
14 / -10
38045
23 / -5
30107
32 / 0
23998
41 / 5
19261
50 / 10
15562
59 / 15
12655
68 / 20
10353
77 / 25
8520
86 / 30
7051
95 / 35
5867
104 / 40
4908
113 / 45
4125
122 / 50
3485
131 / 55
2957
140 / 60
2520
149 / 65
2157
158 / 70
1854
167 / 75
1600
176 / 80
1386
185 / 85
1205
194 / 90
1051
203 / 95
920
212 / 100
808
Visual check Port
Port should show
blue flame.