Water Heater Exhaust Terminal Location

The following information should be used for determining the proper location of 

the vent terminal for outdoor tankless water heaters.

WARNING

Moisture in the flue 

gas

 will condense as it

leaves the vent t

erminal. 

In cold weather this condensate can

fr

eeze 

on the exterior wall, under the eaves and on

surr

ounding objects. Some 

discoloration to the exterior of

the 

building 

is to 

be

 expected. However, i

mpr

oper location

or installation can result in severe 

damage

 to the structure

or exterior finish of the 

building

Additional Considerations

1. Do not install water heater under 

any patio or deck.

2. To help prevent moisture from freez-

ing on walls and under eaves, do not 

locate the water heater on the side 

of a building with prevailing winter 

winds.

3. To help prevent water lines from 

freezing do not locate water heater 

on the side of a building with pre-

vailing winter winds.

4. Do not locate water heater too close 

to shrubbery, as flue gases may dam

-

age them.

5. Caulk all cracks, seams and joints 

within six (6) feet (1.8 m) of exhaust 

vent.

6. Guard exhaust vent against acciden-

tal contact with people and pets.

7. Install the water heater such that the 

air inlet and exhaust vent are above 

anticipated snow levels

Recess Box Location 

- This water heater recess box is intended for an outdoor location only. Follow the 

guidelines below or in the Use and Care Manual provided with the water heater for choosing a suitable location. 

Figure 1

Figure 2

D

V

V

E

FIXE

D

CLO

SED

OPE

RAB

LE

OPE

RAB

LE

FIXE

D

CLOS

ED

v

v

B

L

F

C

B

v

v

v

X

B

B

B

A

J

C

I

H

X

v

M

K

v

G

A

VENT TERMINAL

X AIR SUPPLY INLET

AREA WHERE TERMINAL IS NOT PERMITTED

2

(1.8 m)

If soffit vent is too close,

block off and install new

vent at another location

Inside

corner

Caulk

Caulk

Caulk

6' (1.8 m) 

caulk zone or to edge of

window etc., starting

within 6' (1.8 m)

Rising moisture will collect under eaves

4'

6' (1.8 m) caulk

zone

6'

(1.2 m)

Canadian Installations

1

Indoor and Outdoor

US Installations

 2

Outdoor

A=   Clearance above grade, ve-

randa, porch, deck or balcony.

12 inches (30 cm) above antici-

pated snow level.

12 inches (30 cm) above antici-

pated snow level.

B=   Clearance to window or door 

that may be opened.

6 inches (15 cm) for appliances ≤ 

10,000 Btuh (3 kW), 12 inches (30 

cm) for appliances > 10,000 Btuh 

(3kW) and ≤100,000 Btuh (30kW), 

36 inches (91 cm) for appliances > 

100,000 Btuh (30kW).

6 inches (15 cm) for appliances 

≤ 10,000 Btuh (3 kW), 9 inches 

(23 cm) for appliances > 10,000 

Btuh (3kW) and ≤ 50,000 Btuh 

(15kW), 12 inches (30 cm) 

for appliances > 50,000 Btuh 

(15kW).

C=   Clearance to permanently 

closed window.

*

*

D=   Vertical Clearance to venti-

lated soffit located above the 

terminal within a horizontal 

distance of 2 feet (61 cm) 

from the center line of the 

terminal.

*

*

E=   Clearance to unventilated 

soffit.

*

*

F=  Clearance to outside corner.

*

*

G=  Clearance to  corner.

*

*

H =  Clearance to each side of cen-

ter line extended meter/regu-

lator assembly.

3 feet (91 cm) within a height 15 

feet (4.57 m) above the meter/regu-

lator assembly.

*

I =   Clearance to service regulator 

vent outlet.

3 feet (91 cm)

*

J =   Clearance to nonmechanical 

air supply inlet to building or 

the combustion air inlet to any  

other appliance.

6 inches (15 cm) for appliances 

≤10,000 Btuh (3 kW), 12 inches 

(30 cm) for appliances > 10,000 

Btuh (3kW) and ≤ 100,000 Btuh 

(30kW), 36 inches (91 cm) for ap-

pliances > 100,000 Btuh (30kW).

6 inches (15 cm) for appliances 

≤10,000 Btuh (3 kW), 9 inches 

(23 cm) for appliances > 10,000 

Btuh (3kW) and ≤ 50,000 Btuh 

(15kW), 12 inches (30 cm) for  

appliances > 50,000 Btuh (15kW)

K =   Clearance to mechanical air 

supply inlet.

6 feet (1.83 m)

3 feet (91 cm) above if within 10 

feet (3 m) horizontally.

L =   Clearance above paved 

sidewalk or paved driveway 

located on public property.

Not Allowed

Not Allowed

M =  Clearance under veranda, 

porch, deck or balcony.

Not Allowed

Not Allowed

1

 In accordance with current CAN/CGA-B149 Installation Code

2

 In accordance with current ANSI Z223.1/NFPA National Fuel Gas Code.

*  If clearances are not specified, then follow local installation codes and the requirement of the gas supplier.

**   For condensing appliances: The vent for this appliance shall not terminate over public walkways, near soffit 

vents, crawl space vents, or other areas where condensate or vapor could create a nuisance, hazard or cause 

property damage, or where condensate or vapor could cause damage or could be detrimental to the operation 

of regulators, relief valves or other equipment.