9
HYDRONIC AIR HANDLER ELECTRICAL PHYSICAL SPECIFICATIONS - PSC MODELS
U.S. and Canadian Models
HYDRONIC AIR HANDLER ELECTRICAL PHYSICAL SPECIFICATIONS - ECO-TECH™ MODELS
U.S. and Canadian Models
MODEL NUMBERS
Nominal Heating Capacity BTU/hr [W]
40000
60000
80000
100000
Air Side Temperature Rise* °F [°C]
45-75 [25-41.7]
40-70 [22.2-38.9]
35-65 [19.4-36.1]
35-65 [19.4-36.1]
Heating CFM [L/s] @ .8 WC [.19 kPa]
590 [278]
1000 [471]
1453 [685]
1818 [858]
Cooling CFM [L/s] @ .5 WC [.12 kPa]
1235 [582]
1622 [765]
1871 [883]
1973 [931]
Power Supply (V - HZ - PH)
115 - 60 - 1
Minimum Circuit Ampacity - Amps
9.6
10.9
13.6
13.6
Max Rating of Over Current Protective Device - Amps
15.8
18.2
23
23
Maximum Fuse or Circuit Breaker Size
15
15
20
20
Motor HP [W]
1/2 [373]
3/4 [559]
3/4 [559]
3/4 [559]
Blower (D x W) in [mm]
11 x 7 [279 x 178]
11 x 7 [279 x 178]
11 x 10 [279 x 254]
11 x 10 [279 x 254]
Blower Motor Type
PSC
Pump Type
Wet Rotor
Pump Power Supply (V - HZ - PH)
115 - 60 - 1
Pump Motor RLA/LRA - Amps
1.8
Pump HP [W]
1/8
Pump Maximum Working Pressure psi [kPa]
125 [861]
Min/Max Working Temperature °F [°C]
160 [71]
Water Connection Type
Copper Studs
Inlet Water Connection Diameter in [mm]
3/4 [19]
Out Water Connection Diameter in [mm]
3/4 [19]
Return Air Filter Size in [mm]
12 x 16 [305 x 406]
16 x 24 [406 x 609]
Standard High Velocity Filter Size (L x W x H) in [mm]
15 3/4 x 25 x 1 [400 x 635 x 25]
22 3/4 x 25 x 1 [578 x 635 x 25]
Shipping Weight LBS [kg]
107 [48.5]
118 [53.5]
137 [62.1]
145 [65.7]
RHWB-04WMP36A
RHWB-06WMP48A
RHWB-08WRP60A
RHWB-10WRP60A
MODEL NUMBERS
Nominal Heating Capacity BTU/hr [W]
40000
60000
80000
100000
Air Side Temperature Rise* °F [°C]
45-75 [25-41.7]
40-70 [22.2-38.9]
35-65 [19.4-36.1]
35-65 [19.4-36.1]
Heating CFM [L/s] @ .8 WC [.19 kPa]
578 [272]
1030 [485]
1502 [707]
1847 [870]
Cooling CFM [L/s] @ .5 WC [.12 kPa]
1180 [556]
1300 [612]
1645 [775]
1707 [804]
Power Supply (V - HZ - PH)
115 - 60 - 1
Minimum Circuit Ampacity - Amps
9.6
12.4
12.4
12.4
Max Rating of Over Current Protective Device - Amps
15.8
20.9
20.9
20.9
Maximum Fuse or Circuit Breaker Size
15
20
20
20
Motor HP [W]
1/2 [373]
3/4 [559]
3/4 [559]
3/4 [559]
Blower (D x W) in [mm]
11 x 7 [279 x 178]
11 x 7 [279 x 178]
11 x 10 [279 x 254]
11 x 10 [279 x 254]
Blower Motor Type
EcoTech / ECM Type
Pump Type
Wet Rotor
Pump Power Supply (V - HZ - PH)
115 - 60 - 1
Pump Motor RLA/LRA - Amps
1.8
Pump HP [W]
1/8
Pump Maximum Working Pressure psi [kPa]
125 [861]
Min/Max Working Temperature °F [°C]
160 [71]
Water Connection Type
Copper Studs
Inlet Water Connection Diameter in [mm]
3/4 [19]
Out Water Connection Diameter in [mm]
3/4 [19]
Return Air Filter Size in [mm]
12 x 16 [305 x 406]
16 x 24 [406 x 609]
Standard High Velocity Filter Size (L x W x H) in [mm]
15 3/4 x 25 x 1 [400 x 635 x 25]
22 3/4 x 25 x 1 [578 x 635 x 25]
Shipping Weight LBS [kg]
116 [52.6]
126 [57.2]
146 [66.2]
153 [69.3]
RHWB-04WMX36A
RHWB-06WMXP48A
RHWB-08WRX60A
RHWB-10WRX60A