Rheem Rheem RTG-53DV Specifications Download Page 2

42 & 53 TANKLESS SERIES

Specifications

DESCRIPTION

FEATURES

ROUGHING IN DIMENSIONS (SHOWN IN INCHES)

ENERGY INFO.

GAS

WATER FLOW RATE

VENT

SHIP.

D.O.E. ANN.

MODEL

INPUT

TEMP.

GPM @ 77° GPM @ 45° GPM @ 35°

CONNECTION

DIAMETER

WEIGHT

ENERGY

OP. COST

NUMBER

BTU/HR.

TYPE

RANGE

RISE MAX. RISE MAX. RISE MAX.

WATER

GAS

HEIGHT

WIDTH

DEPTH

(INCHES)

(LBS.)

FACTOR

NAT/LP

RTG2-42PVN†

21,500 -

Indoor

100° to

2.5

4.2

5.5

3/4

3/4

20-1/2

13-3/4

6-1/4

3

35

.83

$220/$369

118,000

140° F

RTG-53PVN

21,500 -

Indoor

100° to

3.1

5.3

6.8

3/4

3/4

20-1/2

13-3/4

6-1/4

3

36

.82

$223/$374

145,000

140° F

RTG-53XN

19,000 -

Outdoor

100° to

3.0

5.3

6.8

3/4

3/4

20-1/2

13-3/4

6-1/4

N/A

36

.82

$223/$374

141,000

140° F

RTG-53DVN

20,000 -

Indoor

100° to

3.0

5.3

6.8

3/4

3/4

23

13-3/4

7-1/4

3 by 5

39

.82

$223/$374

141,000

Direct Vent

140° F

CONCENTRIC

RHEEM TANKLESS WATER HEATERS FOR 1-2 BATHROOM HOMES

All models are available in Natural Gas and Propane (LP).
For Propane replace the N with P when ordering.

* 135,000 for Propane model.
• Factory set maximum temperature is 120° F. See Use and Care Manual for setting.
• For installations above 3,280 feet, a high altitude chip is required. Refer to Rheem price list or consult

factory for details.

• Consult factory for information on sizing the application.

Installation Vent Kits available separately:

3" diameter for RTG2-42PV† and RTG-53PV models.

Vent Termination Kits are required for Direct Vent models. Contact your distributor for details.

Temperature Rise (°F)

Model Number

35°

45°

50°

60°

70°

77°

80°

90° 100°

RTG2-42† Water Flow (GPM)

5.5

4.2

3.8

3.2

2.7

2.5

2.4

2.1

1.9

RTG-53 Water Flow (GPM)

6.8

5.3

4.7

3.9

3.4

3.1

3.0

2.6

2.4

Above estimates are for sizing purposes only.

Proper gas pressure must be ensured to supply tankless gas water heaters – up to 118,000 BTU for
RTG2-42† models, and up to 145,000 BTU for RTG-53 models. (Consult your gas supplier)

Rheem Heating, Cooling & Water Heating
101 Bell Road • Montgomery, AL 36117-4305
1-866-720-2076 • www.rheemtankless.com

Rheem Canada Ltd./Ltée • Water Heater Division
128 Barton Street West, Hamilton, Ontario L8N 3P3

Rheem manufactures residential & commercial heating,
cooling & water heating products.

Printed in U.S.A.

07/08 WP

Form No. 101-50-53CAN

Energy Factor and Average Annual Operating Costs based on D.O.E.
(Department of Energy) test procedures. D.O.E. national average fuel rate
natural gas $1.218/therm; LP $1.87/gallon

.

These units are designed to meet or exceed ANSI (American National Standards Institute)
requirements and have been tested according to D.O.E. test procedures and meet or
exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and
all state energy efficiency performance criteria for energy consuming appliances.

Before purchasing this appliance, read important energy cost and efficiency information
available from your supplier.

In keeping with its policy of continuous progress and product improvement,
Rheem reserves the right to make changes without notice.

Water Heater Flow Rate Curves

0

1

2

3

4

5

6

7

10

15

20

25

30

35

40

45

50

55

60

70

80

90

100

Delta-T

G

PM

53 Max Flow
42 Max Flow

®

† Limited availability in Canada.

Reviews: