BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE
FROM YOUR RETAILER.

PHYSICAL DATA AND SPECIFICATIONS (UPFLOW)
U.S. AND CANADA MODELS

GENERAL TERMS OF LIMITED WARRANTY

Rheem will furnish a replacement for any part of this product
which fails in normal use and service within the applicable
period stated, in accordance with the terms of the limited 
warranty.

For Complete Details of the Limited Warranty, Including Applicable Terms
and Conditions, See Your Local Installer or Contact the Manufacturer for
a Copy.

Gas Heat Exchanger Limited Warranty ......Twenty (20) Years
*Any Other Part.............................................Five (5) Years

*This five year limited warranty is applicable only to single-phase 

products installed in residential applications on or after January 1, 2001.

MODEL IDENTIFICATION—UPFLOW MODELS

[

] Designates Metric Conversions

MODEL NUMBERS
RGPR- SERIES

05EBMKR

05NBMKR

07EAMKR

07NAMKR

10EBRMR

10NBRMR

12EARMR

12NARMR

Temperature Rise Range
°F [°C]

25-55 [13.9-30.6]

30-60 [17-33]

30-60 [17-33]

35-65 [19.4-36.1]

100% High Input–BTU/Hr [kW] 

50,000 [15]

75,000 [22]

100,000 [29]

125,000 [37]

High Heating Capacity–BTU/Hr [kW] 

40,000 [12]

60,000 [18]

80,000 [23]

100,000 [29]

70% Low Input–BTU/Hr [kW]

35,000 [10]

52,500 [15]

70,000 [20]

87,500 [25]

Low Heating Capacity–BTU/Hr [kW]

28,000 [8]

42,000 [12]

56,000 [16]

70,000 [20]

Heating–Ext. Static Pressure [kPa]

.10 [.025]

.15 [.037]

.20 [.05]

.20 [.05]

Blower (D x W) [mm]

11 x 7

[279 x 178]

11 x 7

[279 x 178]

11 x 10

[279 x 254]

11 x 10

[279 x 254]

ECM Motor H.P. [W]

3

/

4

[559]

1

/

2

[373]

1 [746]

1 [746]

Motor Full Load Amps.

9.6

7.7

12.8

12.8

Heating Speed CFM–High Fire [L/s]

850 [401]

1176 [555]

1600 [753]

1832 [865]

Heating Speed CFM–Low Fire [L/s]

625 [295]

980 [462]

1300 [615]

1420 [670]

Cooling CFM @ .5" [kPa] E.S.P.
(Nominal) [L/s]

1200

[566]

1200

[566]

2000

[944]

2000

[944]

Max. E.S.P. (In. W.C.) [kPa]

0.8 [.2]

0.8 [.2]

0.8 [.2]

0.8 [.2]

Max. Outlet Air Temp. °F [°C]

155 [68.3]

165 [73.8]

170 [76.6]

180 [82.2]

Standard Filter Size–Inches
[mm]

15

3

/

4

x 25

[400 x 635]

15

3

/

4

x 25

[400 x 635]

19

1

/

4

x 25

[489 x 635]

22

3

/

4

x 25

[578 x 635]

Return Air Cabinets
(Opt.) RXGR-
Filter Size [mm]

C17B

(2) 12 x 16

[305 x 406]

C17B

(2) 12 x 16

[305 x 406]

C21B

(2) 20 x 16

[508 x 406]

C24B

(2) 24 x 16

[610 x 406]

AFUE 

80%

80%

80%

80%

07EBRQR

07NBRQR

25-55 [13.9-30.6]

75,000 [22]

60,000 [18]

52,500 [15]

42,000 [12]

.15 [.037]

11 x 10

[279 x 254]

3

/

4

[559]

9.6

1305 [616]

1125 [533]

1600

[755]

0.8 [.2]

165 [73.8]

19

1

/

4

x 25

[489 x 635]

C21B

(2) 20 x 16

[508 x 406]

80%

115 [52]

Approx. Shipping Weight (Lbs.) [kg]

110 [50]

115 [52]

120 [54]

140 [63]

15

Maximum Overcurrent Protection

15

15

15

15

12.0

Unit Amps

8.7

8.7

12.0

12.0

20-50 [11.1-27.8]

20-50 [11.1-27.8]

25-55 [13.9-30.6]

30-60 [17-33]

20-50 [11.1-27.8]

High Input
Low Input

➀ 

In accordance with D.O.E. test procedures.

➁ 

See Conversion Kit Index Form for high altitude derate.

G

P

R

Furnace

A

M

K

R

Rheem

Gas

Upflow/

Design

Heating Input Designation

Horizontal

Series

Variations

Blower

Heating & Cooling

Fuel Type

M

= 11 x 7

[279 x 178 mm]

R

= 11 x 10

[279 x 254 mm]

K

= 600-1200 CFM

[283-566 L/s]

M

= 1200-2000 CFM

[566-944 L/s]

Q

= 1000-1600 CFM

[566-944 L/s]

Electric

Ignition

05E
07E
10E
12E

A

= Std.

Cabinet

B

= Wide

Cabinet

Designation

Designation

R

= Natural Gas,

U.S. and
Canadian
Standard
Furnace

Input

BTU/HR

50,000 [15 kW]
75,000 [22 kW]

100,000 [29 kW]
125,000 [37 kW]

NO

x

Model

05N
07N
10N
12N

278

Option Code

for High
Altitude,

(available on

certain models)

R

07E

Summary of Contents for RGPR 05EBMKR

Page 1: ...l Constant CFM Dip switch settings for selectable cooling airflow On demand dehumidification terminal for improved com fort in cooling mode Convertible from upflow to horizontal left or right Left or...

Page 2: ...s optional accessories from a Rheem parts distributor For L P propane operation refer to Conversion Kit Index Form WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES STANDARD...

Page 3: ...1 746 Motor Full Load Amps 9 6 7 7 12 8 12 8 Heating Speed CFM High Fire L s 850 401 1176 555 1600 753 1832 865 Heating Speed CFM Low Fire L s 625 295 980 462 1300 615 1420 670 Cooling CFM 5 kPa E S...

Page 4: ...e with local codes Designates Metric Conversions UPFLOW DIMENSIONS UPFLOW DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL INCHES mm MODEL RGPR A B C D E REDUCED CLEARANCES IN mm 05 07A 171 2 445 1611...

Page 5: ...S AND CLEARANCE TO COMBUSTIBLE MATERIAL INCHES mm WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR INSTALLATION ON ITS BACK WITH ACCESS DOORS FACING UPWARDS MODEL RGPR A B C D E REDUCED CLEARAN...

Page 6: ...5 8 2 05 11 x 7 279 x 178 3 4 559 HIGH MED HI MED LOW 1200 566 1000 472 800 378 600 283 07A 11 x 7 279 x 178 1 2 373 HIGH MED HI MED LOW 1200 566 1000 472 800 378 600 283 10 12 11 x 10 279 x 254 1 746...

Page 7: ...orifices If a burner orifice change is necessary they must be ordered through PROSTOCK See Installation instructions for more information Option 278 furnaces are shipped with 51 DMS orifices installed...

Page 8: ...Provincial and Local codes regulations and practices RHEEM AIR CONDITIONING DIVISION 5600 Old Greenwood Road Fort Smith Arkansas 72908 In keeping with its policy of continuous progress and product im...

Reviews: