9
Forced Air Inlet
4' (1.2 m)
Minimum
3' (0.9 m)
Minimum
10' (3 m)
Minimum
1' (0.3 m)
Minimum
4' (1.2 m)
Minimum
4' (1.2 m)
Minimum
Figure 4.
Clearances
Pagoda Top Installation
1. Insert tabs into keyhole (4 places). See
detail A.
2.
Snap tabs into keyholes so as not to pull out. See
OUTDOOR TOP
(SHIPPED LOOSE WITH HEATER)
DETAIL A
DETAIL B
Figure 5. Outdoor Top Installation
For installations in Florida and Texas,
that must
comply with the Florida or Texas Building Code, follow
the directions shown in
for the installation of
hurricane tie-down brackets for all models.
Indoor Heater Installation
The heater is also design-certified for indoor installation
when equipped with the approved drafthood.
For Canada, indoor installation is restricted to an enclosure
that is not occupied and does not directly communicate
with an occupied area. Refer to the latest edition of CAN/
CSA-B149 for specific requirements. Locate heater as
close as is practical to a chimney or gas vent. Heater
must always be vented to the outside. See section
for details. Minimum allowable
space is shown on the nameplate.
A
A
WARNING:
Indoor heaters require a drafthood that
must be connected to a vent pipe and properly vented to
the outside. Failure to follow this procedure can cause
fire or fatal carbon monoxide poisoning.
Outdoor and Indoor Stacks
The outdoor and indoor stacks are optional equipment
and do not come standard with the heater.
Refer to
installation instructions inside box for instructions on
how to install outdoor/indoor stack.
Outdoor Stack
Indoor Stack
Model
Part No
Part No.
207A
009834
009838
267A
009835
009839
337A
009836
009840
407A
009837
009841
Table D. Outdoor and Indoor Stack Kit Number
OUTDOOR STACK KIT
(1) Outdoor stack, painted
(1) Adapter plate
(3) Mounting brackets (clips)
(1) Top panel cover
(2) 1-foot sections of metal tape
(3) Screws
(1) Instructions
Clips
Figure 6. Outdoor Stack Kit Components
NOTE:
The outdoor drafthood kit does not require any
additional vent pipe for proper operation. This drafthood
functions as the vent termination.
6000.592_PoolSpa_LoNOx.indd 9