UPFLOW AND HORIZONTAL FILTER LOCATION – RECOMMEND

ST-A1194-10-XO

UPFLOW FILTER SIZES

  FURNACE        BOTTOM                SIDE
     WIDTH               SIZE                    SIZE              

QUANTITY

       17

1

2

            15

3

4

X 25

          15

3

4

X 25

                 1

         21

             19

1

4

X 25

          15

3

4

X 25

                 1

       24

1

2

            22

3

4

x 25

          15

3

4

x 25

                 1

FIGURE 7

UPFLOW SIDE FILTER INSTALLATION – RECOMMEND

SIDE RETURN

ST-A1194-11-XO

FIGURE 8

DOWNFLOW/HORIZONTAL ALTERNATE FILTER IINSTALLATION –
RECOMMEND

ST-A1194-12-XO

ELECTRICAL SHOCK, FIRE OR
EXPLOSION HAZARD

Failure to follow safety warnings
exactly could result in danger-
ous operation, serious injury,
death or property damage.

Improper servicing could result
in dangerous operation, serious
injury, death or property dam-
age.

• Before servicing, disconnect all

electrical power to furnace.

• When servicing controls, label

all wires prior to disconnecting.
Reconnect wires correctly.

• Verify proper operation after

servicing.

FIRE, EXPLOSION OR CARBON
MONOXIDE POISONING HAZ-
ARD

Failure to replace with proper
control could result in fire, ex-
plosion or carbon monoxide poi-
soning.

This appliance uses a NEGATIVE
PRESSURE REGULATED gas
control.

Replace ONLY with the same
model number or as specified by
the manufacturer.

!

WARNING

!

WARNING

Summary of Contents for R92P

Page 1: ...chedule and safety procedures CAREFULLY FOLLOW THESE SAFETY RULES 1 Combustible material must not be placed on or against the fur nace jacket The area around the furnace must be kept clear and free of...

Page 2: ...for proper balance and sealing WARNING DO NOT USE THIS FURNACE IF ANY PART HAS BEEN UNDER WATER A FLOOD DAMAGED FURNACE IS EX TREMELY DANGEROUS ATTEMPTS TO USE THE FUR NACE CAN RESULT IN FIRE OR EXPL...

Page 3: ...OPENINGS IN THE STRUCTURE TOXIC FUMES INCLUDING CARBON MONOXIDE CAN ALSO BE DRAWN INTO THE LIVING SPACE THROUGH OPENINGS AND SEAMS IN THE CENTRAL HEATING AND AIR CONDITIONING EQUIPMENT AND OR DUCT WO...

Page 4: ...ain tain the desired temperature OFF Turns heating and cooling modes off The blower may still circulate air in the FAN ON position FAN ON Turns the blower on for continuous operation FAN AUTO The blow...

Page 5: ...place burner access door System Operation FOR YOUR SAFETY READ BEFORE OPERATING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EX ACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY...

Page 6: ...gs exactly could result in danger ous operation serious injury death or property damage Improper servicing could result in dangerous operation serious injury death or property dam age Before servicing...

Page 7: ...ent the possibility of overheating due to an accumulation of dust and dirt on the windings or on the motor exterior And as suggested elsewhere in these instructions the air filters should be kept clea...

Page 8: ...is equipped with a pressure switch which will shut off the main burners if the condensate drain line becomes blocked Be sure this condensate drain line does not become blocked or plugged Visual inspe...

Page 9: ...4 3 3 0 0 8 8 7 6 0 5 3 0 2 1 1 31 1 0 6 1 31 1 4 5 F G9 4 3 0 A 6 6 5 3 45 45 8 45 3 8 8 7 6 0 5 3 2 1 0 7 6 45 6 0 1 45 9 9 8 45 9 61 6 7 E C B D 1 1 C 6 5 B 2 0 G9 H 7 6 F1 J 41K 6 1 6 L 6 1 C M 1...

Page 10: ...10...

Page 11: ...11...

Page 12: ...12 CM 0413...

Reviews: