Rheem PVCG Installation, Operation And Service Manual Download Page 1

 

INSTALLATION, OPERATION, AND SERVICE MANUAL

 

POWER VENT STORAGE TYPE GAS WATER HEATER 

MODELS PVG/PVCG 

 
THESE INSTRUCTIONS ARE INTENDED AS AN AID TO 

QUALIFIED SERVICE PERSONNEL FOR PROPER INSTALLATION, 

ADJUSTMENT AND OPERATION OF THIS WATER HEATER. 

READ THESE INSTRUCTIONS THOROUGHLY BEFORE 

ATTEMPTING INSTALLATION OR OPERATION. FAILURE TO 

FOLLOW THESE INSTRUCTIONS MAY RESULT IN IMPROPER 

INSTALLATION, OPERATION, SERVICE OR MAINTENANCE, 

POSSIBLY RESULTING IN FIRE, ELECTRICAL SHOCK, SCALD 

INJURY, CARBON MONOXIDE POISONING, EXPLOSION, 

PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

 

INSTALLER:   

• 

ATTACH THESE INSTRUCTIONS TO OR ADJACENT TO THE 
WATER HEATER. 

• 

BEFORE LEAVING THE PREMISES REVIEW THIS INSTALLATION, 
OPERATION AND SERVICE MANUAL TO BE SURE THE HEATER 
HAS BEEN INSTALLED CORRECTLY. START AND OPERATE THE 
UNIT FOR ONE COMPLETE CYCLE AND MAKE SURE THE 
WATER TEMPERATURE IS ACCEPTABLE TO THE CONSUMER 
AT THE FIXTURES. 

OWNER: 

• 

RETAIN THESE INSTRUCTIONS AND WARRANTY FOR FUTURE 
REFERENCE. RETAIN THE ORIGINAL RECEIPT AS PROOF OF 
PURCHASE. 

THIS MANUAL IS NOT TO BE USED WITH GAS STORAGE TYPE 
WATER HEATERS CERTIFIED FOR INSTALLATION IN 
MANUFACTURED HOMES (MOBILE HOMES). 

AN ODORANT IS ADDED BY THE GAS SUPPLIER TO THE GAS 
USED BY THIS WATER HEATER

.

 

WARNING

 

AN ODORANT IS ADDED BY THE GAS SUPPLIER TO THE GAS USED BY 
THIS WATER HEATER.

 

THIS ODORANT MAY FADE OVER AN 

EXTENDED PERIOD OF TIME. DO NOT DEPEND UPON THIS ODORANT 
AS AN INDICATION OF LEAKING GAS. IF A GAS LEAK IS SUSPECTED, 
CHECK FOR LEAKS BY USING A CHLORIDE-FREE SOAP AND WATER 
SOLUTION, OR OTHER APPROVED METHOD. IF A LEAK CANNOT BE 
FOUND BUT IS STILL SUSPECTED, FOLLOW THE STEPS UNDER 
"WHAT TO DO IF YOU SMELL GAS" AS OUTLINED ON THIS PAGE. 
FAILURE TO OBSERVE THIS WARNING COULD RESULT IN PROPERTY 
DAMAGE, PERSONAL INJURY, OR DEATH.

 

WARNING

 

THIS WATER HEATER MUST BE BRACED, ANCHORED, OR 
STRAPPED TO AVOID FALLING OR MOVING DURING AN 
EARTHQUAKE. CONTACT LOCAL UTILITIES FOR CODE 
REQUIREMENTS IN YOUR AREA OR CALL THE 800 NUMBER 
SHOWN ON FRONT OF THIS MANUAL AND REQUEST 
INSTRUCTIONS 6600933 FOR EXAMPLES. 

 

Recognize this symbol as an indication of Important Safety 

Information. 

 

WARNING: If the information in these 

instructions is not followed exactly, a fire or 
explosion may result causing property damage, 
personal injury or death. 
Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any 

other appliance. 
WHAT TO DO IF YOU SMELL GAS 

• 

Do not try to light any appliance. 

• 

Do not touch any electrical switch; do not use 

any telephone in your building. 

• 

Immediately call your gas supplier from a 

neighbor’s telephone. Follow the gas 

supplier’s instructions. 

• 

If you cannot reach your gas supplier, call the 

fire department. 

Installation and service must be performed by a 

qualified installer, service agency or the gas 

supplier. 

 
 

TO OBTAIN TECHNICAL, WARRANTY OR SERVICE 
ASSISTANCE  DURING OR AFTER THE INSTALLATION OF 
THIS WATER HEATER, CALL TOLL FREE  

1-800-999-9515. 

WHEN CALLING FOR ASSISTANCE, PLEASE HAVE THE 
FOLLOWING INFORMATION READY: 

1. MODEL 

NUMBER 

2.  7 DIGIT PRODUCT NUMBER 
3. SERIAL 

NUMBER 

4.  DATE OF INSTALLATION 

    

 

 

 

 

 

 

 

 

 

 

6510187 

March 2000 

Supersedes 6510162

 

 

http://waterheatertimer.org/How-to-install-gas-water-heater.html#troubleshoot

 

 

Summary of Contents for PVCG

Page 1: ...FREE SOAP AND WATER SOLUTION OR OTHER APPROVED METHOD IF A LEAK CANNOT BE FOUND BUT IS STILL SUSPECTED FOLLOW THE STEPS UNDER WHAT TO DO IF YOU SMELL GAS AS OUTLINED ON THIS PAGE FAILURE TO OBSERVE T...

Page 2: ...quipped for use with one type gas only Check the data plate near the gas control valve for the correct gas FAILURE TO USE THE CORRECT GAS CAN CAUSE PROBLEMS WHICH CAN RESULT IN DEATH SERIOUS BODILY IN...

Page 3: ...IBLE FLOOR HOWEVER WHEN THIS WATER HEATER IS INSTALLED OVER CARPETING THE CARPETING MUST BE PROTECTED BY A METAL OR WOOD PANEL BENEATH THE WATER HEATER AND EXTENDING BEYOND THE FULL WIDTH AND DEPTH OF...

Page 4: ...W DO NOT SMOKE OR HAVE ANY OPEN FLAME NEAR THE FAUCET AT THE TIME IT IS OPEN REPAIR REPLACEMENT SERVICE AND CLEANING OF WATER HEATER PARTS MUST ONLY BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN IMPO...

Page 5: ...and pressure relief valve or any labels or instruction materials applied to the water heater These labels must remain visible for reference by the user Do not remove these labels as they are a perman...

Page 6: ...mit the water level to a maximum depth of 1 3 4 inches and be two inches wider than the heater and piped to an adequate drain Locate the water heater near a suitable inside drain Outside drains are su...

Page 7: ...s BTUH inputs BTUH INPUT MIN SQ FEET WITH 8 CEILING TYPICAL ROOM SIZE WITH 8 CEILING 30 000 188 9 X 21 45 000 281 14 X 20 60 000 375 15 X 25 75 000 469 15 X 31 90 000 563 20 X 28 105 000 657 20 X 33 1...

Page 8: ...ngs to achieve the required minimum free area Screens must not be smaller than 1 4 inch mesh If the free area through a particular design of louver or grille is known it should be used in calculating...

Page 9: ...please note the following Use only Schedule 40 PVC CPVC or ABS DWV plastic pipe and fittings Maximum vent pipe length is 40 feet with three 90 degree long sweep elbows The minimum clearance from plast...

Page 10: ...S TO ENTER THE HOME RESULTING IN CARBON MONOXIDE POISONING OR DEATH THROUGH THE WALL The vent terminal is a 45 degree elbow This is shipped with the water heater and must be used as the vent terminal...

Page 11: ...es and Automatic Shut off Devices for Hot Water Supply Systems ANSI Z21 22 The function of the temperature and pressure relief valve is to discharge water in large quantities in the event of excessive...

Page 12: ...Heat cannot be applied to the water fittings on the heater as they may contain nonmetallic parts If solder connections are used solder the pipe to the adapter before attaching the adapter to the hot a...

Page 13: ...relief valve on the water heater to discharge or weep due to expansion of the heated water A diaphragm type expansion tank suitable for potable water will normally eliminate this weeping condition Pl...

Page 14: ...e 16 and install as follows 1 Install a readily accessible manual shutoff valve in the gas supply line as recommended by the local utility Know the location of this valve and how to turn off the gas t...

Page 15: ...TANT Subjecting the gas valve thermostat to pressures exceeding 14 W C 1 2 psi 3 7 kPa may cause damage resulting in an extremely hazardous condition If the code requires the gas lines to be tested at...

Page 16: ...Water heater not located near an air moving device VENTILATION AND COMBUSTION AIR SUPPLY Sufficient fresh air supply for proper water heater operation Fresh air not taken from areas that contain nega...

Page 17: ...ve If using liquid propane gas shut off the gas at the L P tank outside of your residence 7 Use an outside phone and immediately call the gas company and the fire department Give your name and address...

Page 18: ...re water heater LIGHTING INSTRUCTIONS 1 STOP It is imperative that you read all the safety warnings before lighting the pilot 2 Remove outer and inner doors 3 Turn the temperature dial counterclockwis...

Page 19: ...rnings before lighting the pilot 2 Remove outer and inner doors 3 Set the thermostat to its lowest setting Rotate clockwise 4 Depress the gas control knob slightly and turn clockwise to OFF If the kno...

Page 20: ...RLY IMPAIRED OR DISABLED MEMBERS AND ANYONE WITH TEMPERATURE SENSITIVE SKIN MAY REQUIRE A LOWER TEMPERATURE SETTING TO REDUCE THE RISK OF SCALD INJURY STACKING Stacking occurs when short draws of hot...

Page 21: ...EEN USED FOR A LONG PERIOD OF TIME GENERALLY TWO WEEKS OR MORE HYDROGEN GAS IS EXTREMELY FLAMMABLE AND CAN IGNITE WHEN EXPOSED TO A SPARK OR FLAME TO PREVENT THE POSSIBILITY OF INJURY UNDER THESE COND...

Page 22: ...on at the thermostat Figure 22 Note that L P gas systems use reverse left handed threads on the manifold tube 6 Grasp the manifold tube and push down slightly to free the manifold pilot tube bleed tub...

Page 23: ...ontrol valve thermostat repeat the previous procedure in reverse order Be sure to use Approved Teflon Tape or Pipe Joint Compound on the gas piping connections and fitting on the back of gas valve tha...

Page 24: ...ower to outlet 5 Replace control cable 6 Temporarily jumper across the two terminal on the switch If the blower operates replace the switch 7 Check voltages Replace if defective 8 Replace blower BLOWE...

Page 25: ...h correct orifice 4 Replace thermostat 5 Turn temperature dial to lower setting 6 Install adequate heater 7 Correct piping dip tube must be in cold inlet 8 Advise customer 9 Clean flue locate source a...

Page 26: ...he proper gas type Natural gas thermostat will be marked FOR NATURAL GAS ONLY Propane gas thermostats will be marked FOR L P GAS ONLY REPAIR PARTS LIST ITEM NO PARTS DESCRIPTION 1 BLOWER MOTOR ASSEMBL...

Page 27: ...27 REPAIR PARTS CONT PARTS ILLUSTRATION...

Reviews: