Rheem PH-16(FISN)(FISP) Use And Care Manual Download Page 28

28

Water Temperature Setting…

Maximum water temperature occurs while 
the burner is on. To determine the water
temperature, turn on a hot water faucet and
place a thermometer in the water stream.
Water temperature at the faucet may vary
depending on season and length of pipe 
from the water heater.

The factory setting of the remote control
temperature range is between 100°F (38°C)
and 120°F (49°C).

The remote control is factory preset to 100°F
(38°C).

To turn the remote control ON or OFF, press
the POWER button.

To adjust the temperature to a required setting,
press the UP arrow temperature button.

Pressing the UP or DOWN temperature
adjustment buttons will change the
temperature set point.

The temperature set point on the remote
control cannot be increased above 112°F
(44°C) when a hot water faucet is in the 
open position.

Notice:

The factory setting allows operating

temperatures between 100°F (38°C) and
120°F (49°C). Temperatures of up to 140°F
(60°C) can be achieved with the MAIN
(UMC-117) remote control and a dip switch
adjustment. Only qualified service personnel
should perform this adjustment. Only factory
authorized remote control(s) should be used.

The hottest temperature water will be at the
hot water faucet closest to the water heater.

Always remember to test the water
temperature with your hand before use and
remember that hotter water increases the risk
of scald injury.

Always supervise young children or others
who are incapacitated.

The water heater is equipped with a device
that will shut off the gas supply to the burner
if the water heater exceeds normal operating
temperatures. Refer to the “Before You Call
For Service” section located near the back of
this manual, or contact your dealer.

WARNING: Should overheating 

occur or the gas supply fail to shut off, 
turn off the manual gas control valve 
to the appliance.

If the water heater has been subjected to fire,
flood, physical damage, or has been under
water, turn off the manual gas shut-off
valve(s), and do not operate the water heater
again until it has been checked by qualified
personnel.

Notice:

The water heater may not operate with

a small water flow. In such case, increase the
water flow. If water heater still does not operate
and hot water faucet is completely open,
increase the temperature setting on the remote
control.

!

°F

PRIORITY

POWER

ON/OFF

100 102 104 106 108 110 112 114 116 118 120*   125 130 135 140  

°F

Higher (Hotter)

Lower (Cooler)

  38   39   40   41   42   43   44   46  47   48   49*     52   54   57   60

°C

*  Temperatures above 120°F (49°C) can be achieved by adjusting the dip

switch. See page 35 for dip switch adjustment.

In Use Indicator
(Lit during operation)

LED Display

(Displays water

temperature and error

codes)

ON/OFF
Indicator

Temperature

Adjustment

Buttons

Priority Indicator

Notice:

The remote control

cannot be turned on when
water is flowing or circulating
through the water heater.

Notice:

Display shows 

°F only.

Summary of Contents for PH-16(FISN)(FISP)

Page 1: ...ecommendations for the proper installation and adjustment of the water heater and two to the owner operator to explain the features operation safety precautions maintenance and troubleshooting of the...

Page 2: ...ce READ THIS MANUAL FOR YOUR RECORDS Write the model and serial numbers here You can find them on a label on the appliance Staple sales slip or cancelled check here Proof of the original purchase date...

Page 3: ...well as other flammable materials and liquids adhesives solvents paint thinners etc and the vapors they produce are extremely dangerous DO NOT handle use or store gasoline or other flammable or combu...

Page 4: ...emote control and a dip switch adjustment Only qualified service personnel should perform this adjustment Only factory authorized remote control s should be used Notice When this water heater is suppl...

Page 5: ...e or LP gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level Before attempting to light the water heater make sure to...

Page 6: ...ON READ ALL INSTRUCTIONS BEFORE USING WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion electric shock or to prevent property damage per...

Page 7: ...which may result in severe burns death or property damage The water heater must be located so it is not subject to physical damage for example by moving vehicles area flooding etc The water heater sho...

Page 8: ...ed or accidentally spilled The water heater should be installed as close as practical to the vent termination to minimize vent length and the number of elbows required for venting The water heater sho...

Page 9: ...ing of conventional frame masonry or metal construction infiltration air is normally adequate for proper combustion and ventilation If the water heater is installed in a confined space provisions for...

Page 10: ...leting the installation and putting the water heater into service DANGER Failure to install the appliance vent adapter and properly vent the water heater to the outdoors as outlined in the Venting sec...

Page 11: ...nce vent adapter manufacturer s instructions Appliance Vent Adapter Water Heater Exhaust Flow A B High Temp Sealant Collar Clamp Draining the Condensate Provision should be made to collect and dispose...

Page 12: ...1 foot 300 mm above opening 6 inches 15 cm for appliances 10 000 Btuh 3 kW 9 inches 23 cm for appliances 10 000 Btuh 3kW and 50 000 Btuh 15kW 12 inches 30 cm for appliances 50 000 Btuh 15kW K Clearanc...

Page 13: ...posed vent pipe of indoor water heaters outside of building Guard vent against accidental contact with people and pets Install outdoor water heater such that air inlet and flue outlet is above anticip...

Page 14: ...walls Reinstall the decorative sheathing around the Wall Thimble This assembly may be painted to match the exterior decor Attach a Rheem approved 3 7 6 cm screened 90 elbow termination to the female...

Page 15: ...vent purchased from the manufacturer Chase Requires 6 15 cm Clearance to Combustibles Firestop Firestop Roof Jack Adjustable Roof Flashing Vent Adapter 3 8 cm Clearance Support Hanger Condensate Trap...

Page 16: ...ate both cold and hot water supply lines DO NOT cover the drain or pressure relief valve To ensure proper operation of the water heater the following water pressure guidelines should be followed Opera...

Page 17: ...nction Installation of unions or flexible copper connections are recommended on the HOT and COLD water lines so that the water heater may disconnect easily for servicing if necessary Install a Check V...

Page 18: ...overn the installation of relief valves If local codes require that a temperature and pressure relief valve should be installed the manufacturer recommends a type 40XL Watts T P relief valve or an equ...

Page 19: ...s Use compound sparingly on male threads only A sediment trap should be installed at the bottom of the gas line Do not use excessive force over 31 5 ft lbs 42 7 Nm in tightening the pipe particularly...

Page 20: ...connect to the water heater Therefore a maximum of three controls can connect to the water heater No other manufacturer s controls are suitable for use with this water heater DO NOT attempt to disasse...

Page 21: ...Place the remote control over the base plate Ensure the projections in the base plate fit into the housings in the remote control Fix the control to the base plate at the bottom of the remote control...

Page 22: ...n servicing controls Wiring errors can cause improper and dangerous operation Verify correct operation after servicing BK 8 R GR Y B O W BR WATER FLOW SENSOR OVER HEAT LIMITER BK GND GND THE CONNECTOR...

Page 23: ...codes or plumbing authority requirements may vary from the instructions or diagrams provided and take precedent over these instructions Vacuum Relief Valve Not Supplied If required install per local c...

Page 24: ...uce the standby heat loss encountered with storage tank heaters This water heater does not store water making an insulation blanket unnecessary The manufacturer s warranty does not cover any damage or...

Page 25: ...upply Gas type matches rating plate Gas supply pressure is sufficient for the water heater Gas line equipped with shut off valve union and sediment trap Approved pipe joint compound used Soap and wate...

Page 26: ...s label 2 Turn off all electric power to the appliance 3 Do not attempt to light the burner by hand 4 Turn the Gas Shutoff Valve located on the outside of the unit clockwise to the OFF position 5 Wait...

Page 27: ...alves are available for reducing point of use water temperature by mixing hot and cold water in branch water lines Contact a licensed plumber or the local plumbing authority for further information Se...

Page 28: ...otter water increases the risk of scald injury Always supervise young children or others who are incapacitated The water heater is equipped with a device that will shut off the gas supply to the burne...

Page 29: ...nance and or cleaning ensure proper operation by turning on a hot water faucet Housekeeping Before performing Housekeeping tasks to this water heater turn the unit off and disconnect the power supply...

Page 30: ...inspect the burner flame Blue flames should be seen when the main burner is firing See figure on left for location of sight glass If any unusual burner operation is noted the water heater should be s...

Page 31: ...eezing conditions even for a short period of time be sure to drain all water from the unit as instructed above Exposure to freezing conditions can occur from down draft of venting system or from insta...

Page 32: ...functions if applicable Check and replace if necessary Error code displayed on remote control See instructions for Error Code and if required contact a dealer for service Not enough water demand Incre...

Page 33: ...as type Improper venting vent material or vent configuration Open the Gas shutoff valve fully Contact gas utility company Fill up LP Gas container or replace with a new cylinder of LP Gas Bleed all ai...

Page 34: ...t connectors or other safety devices Refer repairs to qualified service personnel WARNING For your safety DO NOT attempt to disassemble this unit for any reason Indoor Water Heater Gas Supply Unit Cov...

Page 35: ...then continue as listed below Press the SW2 button on the left hand side of the PCB for more than 1 second The LED on the PCB starts illuminating continuously At the same time the display of the Main...

Page 36: ...f completion of installation the owner shall have a period of thirty 30 days to comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon mono...