Installation

Plumbing and Piping

Follow all instructions in the Use and Care Manual 

for installation of gas and water lines. Knock outs are 

provided in the bottom of the recess box for all piping 

and wiring. These knock outs line up with the fittings 

on the bottom of the water heater.  

1. Stub the water lines and gas pipe up through 

the bottom of the box (See Figure 5). It is 

recommended that shut off valves and unions 

be installed in the piping for future service 

requirements. 

Connect the water lines and gas piping to the 

water heater in accordance with the instructions 

in the Use and Care Manual provided with the 

water heater. 

2. Seal the holes around the piping with a silicone 

based sealant to prevent any water from leaking 

into the wall behind the recess box. Insulate 
pipes with foam insulation.

Typical Rough in Framing

Cripple Stud

King Stud

Trimmer 

Stud

Blocking

Header

Wall Stud

Sill

Rough In Dimensions

Height 47”; Width 20”; Depth depends upon siding on home.

Recess Box Dimensions

A

B

C

D

F

E

* Approximate

Dim.*

Inches

Siding

Lap/Brick

Stucco

A

46”

(117 cm)

46”

(117 cm)

B

19 1/4

(49 cm)

19 1/4

(49 cm)

C

9 1/4”

(24 cm)

9 1/4”

(24 cm)

D

1”

(2.0 cm)

1”

(2.0 cm)

E

23 1/4”

(59 cm)

26 1/4” 

(67 cm)

F

48 3/4”

(124 cm)

51 3/8” 

(131 cm)

Hot Water 

Line

Electrical/

Thermostat 

Wiring  

Openings

Condensate 

Drain line

Relief Valve Drain 

(Alternate)

Gas Line

Cold Water 

Line

Plumbing and Piping Knock Outs

Relief Valve 

Drain

Summary of Contents for ECOH160X

Page 1: ...th Location This water heater recess box is for OUTDOOR installation ONLY and is intended for use only with the water heater models listed above Do not at tempt to install a water heater of another br...

Page 2: ...tor assembly 3 feet 91 cm within a height 15 feet 4 57 m above the meter regulator assembly I Clearance to service regulator vent outlet 3 feet 91 cm J Clearance to nonmechanical air supply inlet to b...

Page 3: ...rminal In cold weather this condensate can freeze on the exterior wall under the eaves and on surrounding objects Some discoloration to the exterior of the building is to be expected However improper...

Page 4: ...e Manual provided with the water heater 2 Seal the holes around the piping with a silicone based sealant to prevent any water from leaking into the wall behind the recess box Insulate pipes with foam...

Page 5: ...hermostat Wiring A hole is provided for the Thermostat wire s Route the wire through the hole and connect the wire to the water heater according to the instructions in the Use and Care Manual Typical...

Page 6: ...Use and Care Manual for complete details about the water heater Check all water and gas connections for leaks Seal all openings around pipes and wires with an outdoor grade silicone sealant Seal the...

Page 7: ...slight angle Slip the door into the channel at the top of the recess box Next push the bottom of the door flush with the recess box and slide down into the channel at the bottom of the enclosure Do n...

Page 8: ...8 Notes...

Reviews: